beautypg.com

VIEWSONIC CD4220 User Manual

Page 51

background image

5.3 Get-Function

Listing

The PC can interrogate the LCD Monitor for specific information. The Get-Function packet format
consists of 5 bytes which is similar to the Set-Function packet structure. Note that the “Value” byte is
always = 00.

Get-Function description:

Length:

Total Byte of Message excluding “CR”

TV ID

Identification for each of TV

Command Type

Identify command type,
“g” (0x67h) : Get Command

Command:

Function command code: One byte ASCII code

Value[1~3]:

Three bytes ASCII that defines the value

CR

0x0D

Get-Function format
Send: (Command Type=”g”)

Name

Length

ID

Command Type

Command

Value1

Value2

Value3

CR

Byte

Count

1 Byte

2 Byte

1 Byte

1 Byte

1 Byte

1 Byte

1 Byte

1 Byte

Bytes

order

1 2~3

4

5

6 7 8 9

Reply: (Command Type=”r” or “-”)

If the Command is valid, Command Type =”r”

Name

Length

ID

Command Type

Command

Value1

Value2

Value3

CR

Byte

Count

1 Byte

2 Byte

1 Byte

1 Byte

1 Byte

1 Byte

1 Byte

1 Byte

Bytes

order

1 2~3

4

5

6 7 8 9

If the Command is Not valid, Command Type=”-“

Name

Length ID Command

Type

CR

Byte

Count

1 Byte

2 Byte

1 Byte

1 Byte

Bytes

order

1 2~3

4

5

Example1: Get Brightness from TV-05 and this command is valid.
The Brightness value is 67.
Send (Hex Format)

Name

Length

ID

Command Type

Command

Value1

Value2

Value3

CR

Hex

0x38 0x30

0x35

0x67 0x62 0x30 0x30 0x30 0x0D

Reply(Hex Format)

Name

Length

ID

Command Type

Command

Value1

Value2

Value3

CR

Hex

0x38 0x30

0x35

0x72 0x62 0x30 0x36 0x37 0x0D


Example2: Get Brightness from TV-05 , but the Brightness command ID is error
and it is NOT in the command table.
Send (Hex Format)

Name

Length

ID

Command Type

Command

Value1

Value2

Value3

CR

Hex

0x38 0x30

0x35

0x67 0XD3 0x30 0x30 0x30 0x0D

Reply (Hex Format)

Name

Length ID Command

Type

CR

Hex

0x34 0x30

0x35

0x2D 0x0D

ViewSonic