cyclic
0,1
6/6
0: Disable cyclic recording
1: Enable cyclic recording
notify
0,1
6/6
0: Disable recording notification
1: Enable recording notification
notifyserver
0~31
6/6
Indicate which notification server is scheduled.
One bit represents one application server (server_i0~i4).
bit0 (LSB) = server_i0.
bit1 = server_i1.
bit2 = server_i2.
bit3 = server_i3.
bit4 = server_i4.
For example, enable server_i0, server_i2, and server_i4
as notification servers; the notifyserver value is 21.
weekday
6/6
Indicate which weekday is scheduled.
One bit represents one weekday.
bit0 (LSB) = Saturday
bit1 = Friday
bit2 = Thursday
bit3 = Wednesday
bit4 = Tuesday
bit5 = Monday
bit6 = Sunday
For example, to detect events on Friday and Sunday, set
weekday as 66.
begintime
hh:mm
6/6
Start time of the weekly schedule.
endtime
hh:mm
6/6
End time of the weekly schedule.
(00:00~24:00 indicates schedule always on)
prefix
string[16]
6/6
Indicate the prefix of the filename.
cyclesize
20~
6/6
The maximum size for cycle recording in Kbytes when
choosing to limit recording size.
reserveamount
15~
6/6
The reserved amount in Mbytes when choosing cyclic
recording mechanism.
dest
cf,
0~4
6/6
The destination to store the recorded data.
“0~4” means the index of the network storage.
Group: path
NAME
VALUE
SECURITY
(get/set)
DESCRIPTION
encoder1_start
7/7
Specify the HTTP push server is active for stream 1
encoder2_start
7/7
Specify the HTTP push server is active for stream 2