Set-Function description:

Length:

Total bytes of message = 5 ASCII (35H) excluding “CR”

Command:

Function command code: One byte ASCII code

Value[1~3]:

Three bytes ASCII that defines the value


Set-Function format:

Name

Length Command Value1 Value2 Value3 CR

Byte Count

1 Byte

1 Byte

1 Byte

1 Byte

1 Byte 1 Byte

Bytes order

1

2

3

4

5

6


All Set-Function from PC to Monitor (ASCII)

Name

Length Command Value1 Value2 Value3 CR

Byte Count

5

1 Byte

1 Byte 1 Byte 1 Byte 00D

Bytes order

1

2

3

4

5

6


Example: Set Mute-ON command (ASCII)

Name

Length Command Value1 Value2 Value3 CR

Byte Count

5

6

0

0

0

00D

Bytes order

1

2

3

4

5

6


Example: Set Mute-OFF command (ASCII)

Name

Length Command Value1 Value2 Value3 CR

Byte Count

5

6

0

0

1

00D

Bytes order

1

2

3

4

5

6

Example: Set Tint to -50 command (ASCII)

Name

Length Command Value1 Value2 Value3 CR

Byte Count

5

-

5

0

00D

Bytes order

1

2

3

4

5

6