beautypg.com

Vita Spa Portable Spa User Manual

Page 23

background image

P

AGE 21

V

. SPA WILL NOT HEAT TO DESIRED

TEMPERATURE

NO

TE that the pump needs to be operating

on

L

OW SPEED

for the heater to come on. If

the pump does not operate, refer to items I
and II.

1. Pump operates on low speed and there

are no diagnostic messages shown on
the display.

Cause:
T

emperature is set too low

Solution:
Set the temperature higher

. The spa water

temperature will rise about 2 degree F.
per hour depending on the season and if it is
indoor or outdoor. Allow enough time for the spa
to reach the desired temperature. Maximum
allowed temperature is 104F.

Cause:
Spa cover is improperly positioned.

Solution:
Y

our spa needs to be covered properly if it is to

heat properly, especially outdoors in cold climate.

Cause:
Filter car

tridge could be dirty and restricting the

water flow intermittently. The diagnostic message

"F

LO"

will appear when this happens but you

might not see it because it is intermittent.

Solution:
Remove the filter car

tridge and clean as

outlined in

"Filt

er Cartridge Removal and

Clean Up"

page 1

3. If this does not solve the

situation, call Service Center for assistance
and mention the code

"L

OW HEAT-1"

2.

Pump operates on low speed and there

is a

"F

LO"

diagnostic message:

"F

LO"

indicates a low water flow or pressure

condition resulting from an obstruction in
the plumbing. Note that the heater is
disabled for safety during that condition.

Cause:
Obstruction in the plumbing.

Solution:

a.

Remove the filter car

tridge and clean it.

See instruction on page 11 If the
condition persists, there could be an

obstruction in the impeller of the
pump. This condition could happen
if the spa is operated without a filter
cartridge. It is important to follow
the

"Filt

er Cartridge Removal and

Cleaning"

instruction of turning the

spa off when removing the filter.
Objects up to 1-1/2" in size could be
sucked through and obstruct the line
or pump impeller.

b. Unplug the therapy module, lift it from

the spa and inspect the plumbing by
opening the unions for blocking
materials such as hair, leaves, string,
plastic bags, etc.

c. If no blocking objects were found

and the

F

LO

message still shows,

there could be a defective or
out-of-calibration pressure switch.
Call Service Center for assistance and
mention the code

"F

LO-1"

3.

Pump low or high speeds do not

operate and there is a

"F

LO"

message.

Call Service center for assistance and
mention the code

"F

LO-2".

4.

Pump operates on low speed and there

is a

"L

S=0, LS=S, SS=0

or S

S=S"

diagnostic message. T

his indicates a

non-functional water or High Limit
temperature sensor. Call the Service
Center for assistance and mention the
code indicated.

VI.

NO WATER FLOW AT JETS AND THE
PUMP IS OPERATING.

Cause:

Loss of prime in the module

Solution:
Prime module by following Priming Instruction on

page 10. (Check the pump unions to make sure
they are not loose.) If this does not solve the
problem, call Service Center for assistance and
mention code

"NO F

LOW-1"