Gga as s c co on nn ne ec ct tiio on n, Bbu ur rn ne er r a ad djju us st tm me en nt t – Viking TruSearTM User Manual
Page 3
3
G
GA
AS
S C
CO
ON
NN
NE
EC
CT
TIIO
ON
N
Verify the type of gas supply to be used, either natural or LP, and make sure the marking on the rating plate
agrees with that of the supply. Never connect an unregulated gas line to the appliance. An installer supplied gas shut-
off valve must be installed in an easily accessible location. All installer supplied parts must conform to local codes, or
in the absence of local codes, with the National electrical Code, ANSI/NFPA 70 and the National Fuel Code, ANSI
Z223.1. IIn
n C
Caan
naad
daa:: Installation must be in accordance with the current CAN/CGA-B149.1, Natural Gas Installation
Code or CAN/CGA-B149.2, Propane Installation Code and/or local codes. All pipe sealants must be an approved type
and resistant to the actions of LP gas. Never use pipe sealant on flare fittings. All gas connections should be made by
a competent technician and in accordance with local codes and or ordinances. In the absence of codes, the installation
must comply with the National Fuel Gas Code ANSI Z223.1.
The gas burner and its individual shut-off valve must be disconnected from the gas supply piping system
during any pressure testing of that system at test pressures in excess of 1/2 PSIG (3.5 kPa). The unit must be isolated
from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of that
system at test pressures equal to or less than 1/2 psi (3.5 kPa).
B
BA
AS
SIIC
C S
SP
PE
EC
CIIF
FIIC
CA
AT
TIIO
ON
NS
S
D
De
essccrriip
pttiio
on
n
V
VG
GIIB
B1
15
51
1T
T
V
VG
GIIB
B2
24
42
2T
T
Overall Width
15-5/16” (38.9 cm)
26 1/4” (66.7 cm)
Overall Depth
To end of landing ledge
31-9/16” (80.2 cm)
To end of knobs
32-5/8” (82.9 cm)
Overall Height
10 1/2” (26.3 cm)
Cutout Width
14” (35.6 cm)
24 3/4” (62.9 cm)
Cutout Depth
27-1/2” (69.9 cm)
Cutout Height
10-1/4” (26.0 cm)
Gas
Natural:
standard residential 1/2” (1.3 cm) ID gas service line.
Requirements
LP/Propane:
equipped with high capacity hose/regulator assembly for
connection to standard 5gal, 20 lb. LP/Propane gas cylinder
with Type 1, QCC-1 connection or standard residential 1/2”
(1.3 cm) ID gas service line.
Infrared Burner
21,500 BTU Nat./20,000 BTU LP
Rating
(6.3 kW Nat./5.9 kW LP)
Approximate Shipping
55 lbs. (24.8 kg)
160 lbs. (72.0 kg)
Weight
F
FLLA
AM
ME
E H
HE
EIIG
GH
HT
T
T
Trru
uS
Se
eaarr B
BU
UR
RN
NE
ER
R
1/4”
(.64 cm)
B
BU
UR
RN
NE
ER
R A
AD
DJJU
US
ST
TM
ME
EN
NT
T
Orifice
There is no burner adjustment for the infrared burner. Once heated, the flames should glow a bright red color.