For a Normally-Open sensor type, attach the
Yellow wire to the remaining Sensor terminal.
Tape back the Brown wire. See Figure 3.

4. Attach the two Red wires to the 24 Vac

terminals in either order.

Important: Most controllers equipped

for sensor connection provide a switch to
control the sensor circuit. Check the
switch setting to ensure that it is not in
the Bypass or Off position.

Wiring Procedure II (no Sensor terminals)

1. Locate the valve common wire terminal,

generally labeled “C” or “COM”, and remove
the attached common wire(s).

2. Attach the White wire to this terminal.

3. Splice the Brown wire to the common

wire(s) using a wire nut or electrical tape.
Tape back the Yellow wire. See Figure 4.

4. Attach the Red wires to the 24 Vac terminals.

7

English

TWRFS-I

Figure 3 - Normally-open Sensor

Figure 4 - Splice Valve Common

Red

White

Brown

Yellow

To Valves

To Valves

Common to Valves
and Pump/MV

Red

Red

White

Y

ellow

Red

Red

White

Brown

Yellow

Red

Red

White

Red

373-0372a_E/S/F 6/7/05 1:59 PM Page 7