U-Line CLR60 User Manual
Page 31

Problem
Possible Cause
Remedy
Unit runs but
Inadequate airflow at
Remove items blocking
produces very
the front of the unit
airflow
little ice
Ice thickness
Adjust ice thickness.
(continued)
adjustment dial
See ADJUSTING ICE
improperly set
THICKNESS
Ice is slow to
Ice-making system
Run unit through
release or does
is dirty
automatic clean cycle.
not release from
See CARE AND
the evaporator
CLEANING
Unit is not level
See LEVELING THE UNIT
Low air temperature
Surrounding air
around unit
temperature must be
at least 50°F (10°C)
Poor ice quality
Poor incoming water
Consult a qualified
(soft or unclear)
quality
plumber to test the
water quality and
recommend appropriate
treatment
Ice-making system is
Run unit through
dirty
automatic clean cycle.
See CARE AND
CLEANING
Unit produces
Low water level
Check to see that
shallow or
overflow tube is fully
incomplete cubes,
seated
or the ice fill
pattern on the
Hot incoming water
Connect the unit to a
evaporator is
cold water supply.
incomplete
See INSTALLATION
Ice thickness
Adjust ice thickness.
adjustment dial
See ADJUSTING ICE
improperly set
THICKNESS
Incorrect incoming
Water pressure must
water pressure
be 20-120 psi
Unit is not level
See LEVELING THE
UNIT
29