If you're looking for the most complete, technologically advanced power protection
unit for the money, the Ultra UPS line is exactly what you need. An Ultra UPS is an
absolute must for anyone running a small server, workstation or a powerful PC. We're
so confident that our UPS will offer you ultimate power protection, it carries a
$125,000 guarantee against damage to any equipment connected to the UPS. You
simply cannot afford to cut corners when it comes to safeguarding your valuable
equipment, and these UPS's deliver the comprehensive protection for computer,
peripherals and data files at a remarkably low price.

300VA

500VA

Gneral

Sku

ULT33061

ULT33062

Backup Time

4-6 minutes (a PC with 15” CRT monitor)
8-12 minutes (a PC with 15” LCD monitor)

7-9 minutes (a PC with 15” CRT monitor)
14-16 minutes (a PC with 15” LCD monitor)

Net Weight Kg (lbs)

1.9(4.2)

2.58(5.67)

Digital Display

No

No

Output

Watts

150

250

UPS Capacity

300VA

500VA

No. of Sockets

Style A UPSx3, Bypassx3

Style A UPSx3, Bypassx3

Voltage (Battery)

Simulated sine wave at 120V +/- 5%

Simulated sine wave at 120V +/- 5%

Frequency (Battery)

50 or 60Hz +/- 0.3Hz

50 or 60Hz +/- 0.3Hz

Transfer Time

2-4 milliseconds, including detection time

2-4 milliseconds, including detection time

Input

Voltage (Single Phase)

120V +15%/-20% at line input

120V +15%/-20% at line input

Frequency

50 or 60Hz +/- 10% (auto sensing)

50 or 60Hz +/- 10% (auto sensing)

Protection

Unit Input

Circuit breaker for overload & short circuit protection

Circuit breaker for overload & short circuit protection

Overload Protection

AC Mode: If load exceeds 110% of nominal, Buzzer
beeps continuously.
Backup Mode: If load exceeds 110% of nominal for 1
second, UPS shuts down automatically.

AC Mode: If load exceeds 110% of nominal, Buzzer
beeps continuously. If load exceeds 120% of nominal for
30 seconds, 130% for 3 seconds, UPS shuts down
automatically.
Back up Mode: If load exceeds 105% of nominal for 20
seconds, 120% for 10 seconds, 130% for 3 seconds,
UPS shuts down automatically.

Short Circuit

UPS output shuts off immediately

UPS output shuts off immediately

Surge Protection

1140 Joules, 2ms

1140 Joules, 2ms

Battery

Type

Sealed, maintenance-free lead acid battery, with 3-6
years typical lifetime

Sealed, maintenance-free lead acid battery, with 3-6
years typical lifetime

Typical Recharge Time

4 hours (to 90% of full capacity)

6 hours (to 90% of full capacity)

Protection

Automatic self-test, Over discharge protection, short
circuit protection by fuse

Automatic self-test, Over discharge protection, short
circuit protection by fuse

Interface

USB

Battery low detecting, UPS on/off scheduling AC
input/output power status display.

Battery low detecting, UPS on/off scheduling AC
input/output power status display.

Alarm

Battery Backup

Slow beeping sound every 4 seconds

Slow beeping sound every 4 seconds

Battery Low

Rapid beeping sound every second

Rapid beeping sound every second

Abnormal Charge

AC Mode: Rapid beeping sound every 0.5 second

AC Mode: Rapid beeping sound every 0.5 second

Overload

Continuous beeping sound

Continuous beeping sound

Environment Ambient Operation

3,500 meters max. elevation, 0-95% humidity non-
condensing, 0-40?

3,500 meters max. elevation, 0-95% humidity non-
condensing, 0-40?

Audible Noise

<40dBA (1 meter from surface)

<40dBA (1 meter from surface)

700VA

850VA

ULT33063

ULT33064

9-11 minutes (a PC with 15” CRT monitor)
17-19 minutes (a PC with 15” LCD monitor)

16-20 minutes (a PC with 15” CRT monitor)
36-40 minutes (a PC with 15” LCD monitor)

2.58(5.67)

4.1(9.1)

No

No

350

425

700VA

850VA

Style A UPSx3, Bypassx3

Style A UPSx4, Bypassx4

Simulated sine wave at 120V +/- 5%

Simulated sine wave at 120V +/- 5%

50 or 60Hz +/- 0.3Hz

50 or 60Hz +/- 0.3Hz

2-4 milliseconds, including detection time

2-4 milliseconds, including detection time

120V +15%/-20% at line input

120V +15%/-20% at line input

50 or 60Hz +/- 10% (auto sensing)

50 or 60Hz +/- 10% (auto sensing)

Circuit breaker for overload & short circuit protection

Circuit breaker for overload & short circuit protection

AC Mode: If load exceeds 110% of nominal, Buzzer
beeps continuously. If load exceeds 120% of nominal for
30 seconds, 130% for 3 seconds, UPS shuts down
automatically.
Back up Mode: If load exceeds 105% of nominal for 20
seconds, 120% for 10 seconds, 130% for 3 seconds,
UPS shuts down automatically.

AC Mode: If load exceeds 110% of nominal, Buzzer
beeps continuously. If load exceeds 120% of nominal for
30 seconds, 130% for 3 seconds, UPS shuts down
automatically.
Back up Mode: If load exceeds 105% of nominal for 20
seconds, 120% for 10 seconds, 130% for 3 seconds,
UPS shuts down automatically.

UPS output shuts off immediately

UPS output shuts off immediately

1140 Joules, 2ms

1520 Joules, 2ms

Sealed, maintenance-free lead acid battery, with 3-6
years typical lifetime

Sealed, maintenance-free lead acid battery, with 3-6
years typical lifetime

6 hours (to 90% of full capacity)

6 hours (to 90% of full capacity)

Automatic self-test, Over discharge protection, short
circuit protection by fuse

Automatic self-test, Over discharge protection, short
circuit protection by fuse

Battery low detecting, UPS on/off scheduling AC
input/output power status display.

Battery low detecting, UPS on/off scheduling AC
input/output power status display.

Slow beeping sound every 4 seconds

Slow beeping sound every 4 seconds

Rapid beeping sound every second

Rapid beeping sound every second

AC Mode: Rapid beeping sound every 0.5 second

AC Mode: Rapid beeping sound every 0.5 second

Continuous beeping sound

Continuous beeping sound

3,500 meters max. elevation, 0-95% humidity non-
condensing, 0-40?

3,500 meters max. elevation, 0-95% humidity non-
condensing, 0-40?

<40dBA (1 meter from surface)

<40dBA (1 meter from surface)

Features

- AVR (Automatic Voltage Regulation)
- Fully Digitized Microprocessor Controlled
- Protects up to 4 Devices at Once
- Energy Saving Function (UPS Green Mode)
- 50/60Hz Frequency Auto Sensing and Selection
- USB Communication Port
- Advanced Battery Management (ABM Technology)

Includes

UPS Monitoring

Software

1-800-830-0051

www.ultraproducts.com

This manual is related to the following products: