Ultra Products ULT33063 User Manual
Uninterrupted power supply (ups), Includes ups monitoring software
Uninterrupted
Power Supply (UPS)
The Ultimate Power Protection!
If you're looking for the most complete, technologically advanced power protection
unit for the money, the Ultra UPS line is exactly what you need. An Ultra UPS is an
absolute must for anyone running a small server, workstation or a powerful PC. We're
so confident that our UPS will offer you ultimate power protection, it carries a
$125,000 guarantee against damage to any equipment connected to the UPS. You
simply cannot afford to cut corners when it comes to safeguarding your valuable
equipment, and these UPS's deliver the comprehensive protection for computer,
peripherals and data files at a remarkably low price.
300VA
500VA
Gneral
Sku
ULT33061
ULT33062
Backup Time
4-6 minutes (a PC with 15” CRT monitor)
8-12 minutes (a PC with 15” LCD monitor)
7-9 minutes (a PC with 15” CRT monitor)
14-16 minutes (a PC with 15” LCD monitor)
Net Weight Kg (lbs)
1.9(4.2)
2.58(5.67)
Digital Display
No
No
Output
Watts
150
250
UPS Capacity
300VA
500VA
No. of Sockets
Style A UPSx3, Bypassx3
Style A UPSx3, Bypassx3
Voltage (Battery)
Simulated sine wave at 120V +/- 5%
Simulated sine wave at 120V +/- 5%
Frequency (Battery)
50 or 60Hz +/- 0.3Hz
50 or 60Hz +/- 0.3Hz
Transfer Time
2-4 milliseconds, including detection time
2-4 milliseconds, including detection time
Input
Voltage (Single Phase)
120V +15%/-20% at line input
120V +15%/-20% at line input
Frequency
50 or 60Hz +/- 10% (auto sensing)
50 or 60Hz +/- 10% (auto sensing)
Protection
Unit Input
Circuit breaker for overload & short circuit protection
Circuit breaker for overload & short circuit protection
Overload Protection
AC Mode: If load exceeds 110% of nominal, Buzzer
beeps continuously.
Backup Mode: If load exceeds 110% of nominal for 1
second, UPS shuts down automatically.
AC Mode: If load exceeds 110% of nominal, Buzzer
beeps continuously. If load exceeds 120% of nominal for
30 seconds, 130% for 3 seconds, UPS shuts down
automatically.
Back up Mode: If load exceeds 105% of nominal for 20
seconds, 120% for 10 seconds, 130% for 3 seconds,
UPS shuts down automatically.
Short Circuit
UPS output shuts off immediately
UPS output shuts off immediately
Surge Protection
1140 Joules, 2ms
1140 Joules, 2ms
Battery
Type
Sealed, maintenance-free lead acid battery, with 3-6
years typical lifetime
Sealed, maintenance-free lead acid battery, with 3-6
years typical lifetime
Typical Recharge Time
4 hours (to 90% of full capacity)
6 hours (to 90% of full capacity)
Protection
Automatic self-test, Over discharge protection, short
circuit protection by fuse
Automatic self-test, Over discharge protection, short
circuit protection by fuse
Interface
USB
Battery low detecting, UPS on/off scheduling AC
input/output power status display.
Battery low detecting, UPS on/off scheduling AC
input/output power status display.
Alarm
Battery Backup
Slow beeping sound every 4 seconds
Slow beeping sound every 4 seconds
Battery Low
Rapid beeping sound every second
Rapid beeping sound every second
Abnormal Charge
AC Mode: Rapid beeping sound every 0.5 second
AC Mode: Rapid beeping sound every 0.5 second
Overload
Continuous beeping sound
Continuous beeping sound
Environment Ambient Operation
3,500 meters max. elevation, 0-95% humidity non-
condensing, 0-40?
3,500 meters max. elevation, 0-95% humidity non-
condensing, 0-40?
Audible Noise
<40dBA (1 meter from surface)
<40dBA (1 meter from surface)
700VA
850VA
ULT33063
ULT33064
9-11 minutes (a PC with 15” CRT monitor)
17-19 minutes (a PC with 15” LCD monitor)
16-20 minutes (a PC with 15” CRT monitor)
36-40 minutes (a PC with 15” LCD monitor)
2.58(5.67)
4.1(9.1)
No
No
350
425
700VA
850VA
Style A UPSx3, Bypassx3
Style A UPSx4, Bypassx4
Simulated sine wave at 120V +/- 5%
Simulated sine wave at 120V +/- 5%
50 or 60Hz +/- 0.3Hz
50 or 60Hz +/- 0.3Hz
2-4 milliseconds, including detection time
2-4 milliseconds, including detection time
120V +15%/-20% at line input
120V +15%/-20% at line input
50 or 60Hz +/- 10% (auto sensing)
50 or 60Hz +/- 10% (auto sensing)
Circuit breaker for overload & short circuit protection
Circuit breaker for overload & short circuit protection
AC Mode: If load exceeds 110% of nominal, Buzzer
beeps continuously. If load exceeds 120% of nominal for
30 seconds, 130% for 3 seconds, UPS shuts down
automatically.
Back up Mode: If load exceeds 105% of nominal for 20
seconds, 120% for 10 seconds, 130% for 3 seconds,
UPS shuts down automatically.
AC Mode: If load exceeds 110% of nominal, Buzzer
beeps continuously. If load exceeds 120% of nominal for
30 seconds, 130% for 3 seconds, UPS shuts down
automatically.
Back up Mode: If load exceeds 105% of nominal for 20
seconds, 120% for 10 seconds, 130% for 3 seconds,
UPS shuts down automatically.
UPS output shuts off immediately
UPS output shuts off immediately
1140 Joules, 2ms
1520 Joules, 2ms
Sealed, maintenance-free lead acid battery, with 3-6
years typical lifetime
Sealed, maintenance-free lead acid battery, with 3-6
years typical lifetime
6 hours (to 90% of full capacity)
6 hours (to 90% of full capacity)
Automatic self-test, Over discharge protection, short
circuit protection by fuse
Automatic self-test, Over discharge protection, short
circuit protection by fuse
Battery low detecting, UPS on/off scheduling AC
input/output power status display.
Battery low detecting, UPS on/off scheduling AC
input/output power status display.
Slow beeping sound every 4 seconds
Slow beeping sound every 4 seconds
Rapid beeping sound every second
Rapid beeping sound every second
AC Mode: Rapid beeping sound every 0.5 second
AC Mode: Rapid beeping sound every 0.5 second
Continuous beeping sound
Continuous beeping sound
3,500 meters max. elevation, 0-95% humidity non-
condensing, 0-40?
3,500 meters max. elevation, 0-95% humidity non-
condensing, 0-40?
<40dBA (1 meter from surface)
<40dBA (1 meter from surface)
Features
- AVR (Automatic Voltage Regulation)
- Fully Digitized Microprocessor Controlled
- Protects up to 4 Devices at Once
- Energy Saving Function (UPS Green Mode)
- 50/60Hz Frequency Auto Sensing and Selection
- USB Communication Port
- Advanced Battery Management (ABM Technology)
Includes
UPS Monitoring
Software
1-800-830-0051