Series 600 POS Keyboard
47
Table 5. Remote Programming Mode Commands
OP CODE
(HEX)
MNEMONIC/DESCRIPTION
COMMAND/ACKNOWLEDGEMENT
B0
LIGHT
Provides on/off control for keyboard light
emitting diode (LED) indicators. PC mode
for NUM and CAP Lock lights is default.
COMMAND:
B0Lx
B0
= Op Code
L
= lamp
x
= on/off
= terminate command (0D hex)
L:
0, 1, 2, 3, P in ASCII, where 0 = all. P is
used for PC emulation of NUM and CAPS
Lock
x:
PC mode
1 = on; 0 = off
ACKNOWLEDGEMENT: NONE