beautypg.com

Ultimate Technology 600 POS User Manual

Page 51

background image

Series 600 POS Keyboard

46

Table 5. Remote Programming Mode Commands

OP CODE

(HEX)

MNEMONIC/DESCRIPTION

COMMAND/ACKNOWLEDGEMENT

AD

RAWED


Puts keyboard in row and column mode
used for diagnostics.

COMMAND:

ADx


AD

= Op Code

x

0 = user codes

1 = row and column

= terminate command (0D hex)


ACKNOWLEDGEMENT: NONE

AE

SECURE


Used to lock keyboard from remote
location.

COMMAND:

AEx


AE

= Op Code

x

0 = unsecured

1 = secured

= terminate command (0D hex)


ACKNOWLEDGEMENT: NONE

AF

COMMENT

Use when notes or comments are to be
placed in the download file. All data is
ignored up to the carriage return .

COMMAND:

AFxxxx-xxxx


AF

= Op Code

xx

= Comments

= terminate command (0D hex)


ACKNOWLEDGEMENT: NONE