Ultimate Technology 600 POS User Manual
Page 51

Series 600 POS Keyboard
46
Table 5. Remote Programming Mode Commands
OP CODE
(HEX)
MNEMONIC/DESCRIPTION
COMMAND/ACKNOWLEDGEMENT
AD
RAWED
Puts keyboard in row and column mode
used for diagnostics.
COMMAND:
ADx
AD
= Op Code
x
0 = user codes
1 = row and column
= terminate command (0D hex)
ACKNOWLEDGEMENT: NONE
AE
SECURE
Used to lock keyboard from remote
location.
COMMAND:
AEx
AE
= Op Code
x
0 = unsecured
1 = secured
= terminate command (0D hex)
ACKNOWLEDGEMENT: NONE
AF
COMMENT
Use when notes or comments are to be
placed in the download file. All data is
ignored up to the carriage return
COMMAND:
AFxxxx-xxxx
AF
= Op Code
xx
= Comments
= terminate command (0D hex)
ACKNOWLEDGEMENT: NONE