U-Line BI95 User Manual
Page 18
Level & Install Unit
17
Installation Troubleshooting
Problem
Q:
Water is leaking under the unit.
Solution
A:
A water leak under the unit is most likely caused by a bad
connection in the water supply line. Make sure the water line’s
brass fitting is screwed tight to its valve and threaded correctly.
Make sure that plumbers tape was NOT used; if it was remove all
traces before reinstalling.
BI-2115 Specific
Problem
Q:
The door remains open unless it is pushed closed.
Solution
A:
The hinges should be self-closing when the door is open
approximately 8". If this is not the case, make sure the closers are
clean, greased and installed correctly. Also, re-check leveling from
front to back of the unit and readjust if necessary. Make sure that
pivot plate is installed correctly.
Problem
Q:
The custom overlay door was designed to align with the rest of the
cabinet doors, but the unit has crept forward.
Solution
A:
Make sure that the electrical cord and water supply line are not
obstructing the installation.