beautypg.com

Electrical specifications, Checking door alignment, Adjusting door alignment – U-Line BI95 User Manual

Page 15: 10 power supply, 9 adjust door, Warning, Important

background image

U-Line Other Requirements

14

9

Electrical Specifications

WARNING

SHOCK HAZARD — Electrical Grounding Required.

• Never remove the round grounding prong from the

plug and never use a two-prong grounding adapter.

• Never use an extension cord to connect power to the

unit.

IMPORTANT

IMPORTANT

Electrical installation must observe all state and local
codes. This unit requires connection to a grounded (three-
prong), polarized receptacle that has been placed by a
qualified electrician.

The unit requires a grounded and polarized 115 VAC, 60 Hz, 15A
power supply (normal household current). An individual, properly
grounded branch circuit or circuit breaker is recommended. GFCI
(ground fault circuit interrupter) is usually not required for fixed
location appliances and is not recommended for your unit because
a GFCI could be prone to nuisance tripping. However, be sure to
consult your local codes.

10 Power Supply






Checking Door Alignment

The unit’s door is aligned at the factory before shipment. However,
its alignment could have been disturbed during shipment.

IMPORTANT

IMPORTANT

Properly aligned, the door’s gasket should be firmly in
contact with the cabinet all the way around the door (no
gaps).

1. Carefully examine the door’s gasket to assure that it is firmly in

contact with the cabinet.

2. When inspecting door alignment, make sure the door gasket is

not pinched on the hinge side of the door.

Adjusting Door Alignment

BI-2115

1. Remove top hinge screw pin Remove door by tilting forward

and lifting off bottom hinge pin.

2. With door upside-down, loosen but do not remove the two

screws on the door’s bottom hinge plate.

3. If the top far edge of the door

needs to move UP, move the
hinge plate toward the outside
of the door and retighten
screws. If the top far edge of
the door needs to move
DOWN, move the hinge plate
toward the inside of the door
and retighten screws.

4. Mount the door to recheck

alignment and repeat Steps 2
and 3 if further adjustment is
necessary.

5. When top edge of door is

parallel to top edge of cabinet,
remove the door and ensure
the two screws are secure.

6. Remove the door closers

from the bottom hinge, clean
thoroughly and lubricate the mating surfaces with petroleum
jelly.

7. Reinstall the closers, lining up the bosses with holes in hinge and

hinge plate.

8. Mount the door, install top hinge pivot pin

All Other Models

1. Loosen (do not remove) top and bottom hinge screws.

2. Align door squarely with cabinet. Make sure gasket is firmly in

contact with cabinet all the way around the door (no gaps).

3. Tighten bottom hinge screws.

4. Tighten top hinge screws.

9 Adjust Door

Door

Closer

Inserts

Boss

Notch

(must face toward

center of door)

Slotted

Mounting

Holes

Raise

Outside

Door Edge

Lower

Outside

Door Edge

23-1/8"

1-1/2"

7"

ADA15IM

BI95, WH95TP, BI95BTP & BCM95

18-1/2"

Minimum

1-1/2"

7"

21-1/2"

Minimum

4"

7"

BI98

SS-1095(NF)(FC)(FD)

BI2115

1-1/2"

7"

26-5/16" Minimum

SP18

Acceptable

Location

Preferred

Location

for Receptacle

1-1/2"

7"

24"

1"

7"

This manual is related to the following products: