beautypg.com

Troubleshooting guide – U-Line BI2115 User Manual

Page 15

background image

BI2115

15

Troubleshooting Guide

DANGER

ELECTROCUTION HAZARD
Never attempt to repair or perform maintenance on
the unit until the main electrical power has been
disconnected.

Troubleshooting - What to check when problems occur:

PROBLEM

POSSIBLE CAUSE

REMEDY

The unit frosts up.

High ambient temperatures or
humidity

Defrost unit manually (See MAINTENANCE;
DEFROSTING).

Unit is a manual defrost unit.

Model BI2115 is a manual defrost unit (See
MAINTENANCE; DEFROSTING).

Door gasket not sealing properly

Adjust door (See MAINTENANCE; DOOR ALIGNMENT
CHECK AND ADJUSTMENT and DOOR REVERSAL).

Water is leaking out the back of the
unit.

Water supply connection leaking

Tighten fitting as required.

Ice cubes sticking together

Infrequent use of cubes

Break apart cubes.

Noise during operation

Copper water supply tubing
contacting internal components

Carefully bend tubing away from cabinet and
components.

Certain sounds are normal.

Soft sounds from the fan and ice dropping from the ice
maker will be heard.

No ice

Bin arm locked in upright position

Lower bin arm.

No water to unit

Turn on water or contact plumber.

Not enough ice

Ice cube size too large

Set cube size smaller (See MAINTENANCE; ICE MAKER;
ICE CUBE THICKNESS ADJUSTMENT).

Dirty condenser coils

Clean condenser (See MAINTENANCE; CONDENSER
CLEANING).

Airflow to front grille blocked

Airflow must not be obstructed to front grille (See
OPERATION).

Temperature not set cold enough

Set control to cooler setting (See OPERATION). Allow 24
hours for temperature to stabilize (See OPERATION).

Water leaks into ice bucket.

Water level set too high

Set cube size smaller (See MAINTENANCE; ICE MAKER;
ICE CUBE THICKNESS ADJUSTMENT).