10

BI2115

To defrost:

1. Turn unit off.

2. Remove ice bucket and discard ice.

3. Place a towel or other absorbent material on bottom of

unit (Figure 5, 1).

4. If you would like, place warm water inside ice bucket.

Then place ice bucket back into unit and close door.

5. After approximately one hour, remove ice bucket and

discard water.

6. Allow the frost to completely melt naturally. Clean the

interior and ice bucket using a mild non-abrasive
detergent and warm water solution applied with a soft
sponge or non-abrasive cloth. NOTE: DO NOT use any
solvent-based or abrasive cleaners. They will discolor or
damage the interior.

7. Dampen a soft sponge or non-abrasive cloth in clean

water and wipe down the cabinet interior and ice
bucket to remove any detergent residue. Rinse the
sponge or cloth in clean water and repeat as necessary
until the cabinet and ice bucket are clean.

IMPORTANT

IMPORTANT

DO NOT place ice bucket in dishwasher. Dishwasher
will warp/discolor ice bucket and render it useless.

8. When the interior is dry, turn unit back on.

NOTE: To safeguard against contaminants in ice,
discard first three batches of ice made after defrosting
unit.

Condenser Cleaning

Interval - Every Three Months
To maintain operational efficiency, keep the front grille
free of dust and lint and clean the condenser every three
months. Depending on environmental conditions, more
or less frequent cleaning may be necessary.

WARNING

Disconnect electric power to the unit before
cleaning the condenser.

To remove and replace the grille for access to the
condenser fins, follow this procedure:

Figure 6

1. Disconnect electrical power to the unit.

2. Loosen two screws (Figure 6, 1) completely.

NOTE: Screws are held in the grille by o-ring retainers,
and will not come free of the grille.

3. Remove the grille.

WARNING

DO NOT touch the condenser fins. The condenser
fins are SHARP and can be easily damaged.

CAUTION

DO NOT use any type of cleaner on the condenser
unit.

4. Clean the condenser coil (Figure 6, 2) using a soft

brush with a “combing” action or vacuum cleaner. Do
not touch the condenser coil.

5. Position the grille to align the mounting screws with

the holes in the cabinet.

6. Secure, but do not over-tighten both grille screws.

7. Reconnect power to the unit.

Ice Maker Maintenance

Inlet Screen

Interval - Every Twelve Months
The solenoid valve inlet screen must be cleaned at least
once each year as follows:

1. Shut off the water at the main supply valve.

2. Pull the unit out to access the back panel.

3. Disconnect electrical power to the unit.

Figure 7

4. Disconnect the hose connector (Figure 7, 1) from the

water solenoid valve (Figure 7, 2).

5. DO NOT remove the inlet screen from the water

solenoid valve. Use a tooth brush to gently clean any
sediment from the inlet screen.

6. Re-connect the water supply hose connector (Figure

7, 1) to the water solenoid valve (Figure 7, 2). Tighten
the connector securely.

ULIN_0203_A

2

1

2

1

ULIN_0054_A