Problem
Possible Cause
Remedy
Unit runs but
Dirty condenser coils.
Clean the condenser.
produces very
Refer to PERIODIC
little ice.
CLEANING AND USER
MAINTENANCE.
High air temperature
Surrounding air
around unit.
temperature of over
90°F (32°C). Low ice
production at high
temperatures is normal.
Scale and mineral
Clean unit. Refer to
buildup in unit.
PERIODIC CLEANING
AND USER
MAINTENANCE.
Inadequate airflow at
Remove items blocking
the front of the unit.
airflow.
Cleaning Cycle recently
Allow unit to reach the set
performed.
temperature to produce ice
normally.
Ice is slow to
Ice-making system
Run unit through
release or does
is dirty.
automatic clean cycle.
not release from
Refer to PERIODIC
the evaporator.
CLEANING AND
USER MAINTENANCE.
Poor ice quality.
Unit is not level.
Refer to LEVELING THE
(soft or unclear)
UNIT.
Poor incoming water
Consult a qualified
quality.
plumber to test the
water quality and
recommend appropriate
treatment.
Ice-making system is
Run unit through
dirty.
automatic clean cycle.
Refer to PERIODIC
CLEANING AND
USER MAINTENANCE.