CONNECTING A DRAIN PUMP

If a gravity drain connection is not available, and you have not
purchased the CLRCO2075 with factory installed pump, we strong-
ly recommend the use of the U-Line P60 drain pump.
The U-Line
P60 drain pump is available through your Dealer, or direct from U-Line
with complete installation instructions. If a pump other than the U-Line
P60 drain pump is to be used, it must meet the following specifica-
tions:

• It must be UL listed and have a UL listed, 120 VAC, 3-wire

grounded power cord.

• It must have overall maximum outside dimensions of 8-3/4" wide x

5-3/4" deep x 7-3/4" high.

• It must have a minimum flow rate of 15 gallons per hour at 10 feet

of lift.

• It must have a sealed sump which does not allow water leakage in

the case of a power outage, restricted drain or pump failure.

• It must have a check valve in the discharge line to prevent waste

water return to the pump.

• It must have an overflow protection control which will shut off power

to the ice maker in the event of a pump failure.

• It must have an operating temperature range of 50°F to 110°F

(10°C to 40°C).

In the event of a power outage, restricted drain or pump
failure, the failure to use the U-Line P60 drain pump or a
pump with the above listed specifications, could result in
substantial water leakage and pooling with severe and
costly water damage and related consequential damages
and harm.

CAUTION