5 nozzle replacement, 6 adjusting control knobs – Fagor 6FI-4GLSX User Manual
Page 9

INSTALLATION
UK
8
ATTENTION !
1. Checking the leakage with an open flame (e.g. with a match or a candle) is
unacceptable. It may lead to an explosion !
2. Check condition of the hose and connection tightness regularly, according to the
valid regulations.
2.5 NOZZLE REPLACEMENT
ATTENTION !
Before nozzle replacement and adjustments, disconnect the hob from the mains.
Nozzle diameters for particular gas type are shown in Table 2.
Table 2
AUX
burner
SR burner
R burner
TC burner
G 20 20 mbar
X072 Z097 Y118 K1,35
G 30/31 29/37 mbar
050 065 085 098
The hob is adjusted to the type of gas and pressure stated on the appliance's rating plate.
In the event of a change of the type of gas replace the nozzles and adjust the taps.
Before beginning these activities you must:
–
shut down the cock shutting off the gas supply system or cylinder from the hob,-shut
down all the taps in the hob,
–
disconnect the hob from the mains.
Then:
–
remove the burners' lids and rings,
–
remove the nozzles with socket wrench no. 7 and replace them with new ones in
accordance with table2,
–
put burners' rings and lids back,-
adjust the taps and check the connections for soundness
Fig. 12
2.6 ADJUSTING CONTROL KNOBS
ADJUSTING THE TAPS
The adjustment of a gas tap consists in setting the burner flame in the simmering position. To
adjust the taps remove all the knobs and control panel.