beautypg.com

U-Line 75 User Manual

Page 14

background image

User’s Manual

CONNECTING THE WATER SUPPLY -

ICE MAKER MODELS ONLY

Install a 1/4" outside diameter copper water line (not
supplied with unit) from the nearest COLD water pipe. When
connecting the water supply, follow these guidelines:

• Review the local plumbing codes before you install the unit.
• In most instances, the cold water supply will come from the

basement through a hole in the floor.

• The water pressure should be between 15 and 150 psi.
• Install a shut-off valve in the 1/4" outside diameter supply line

(not supplied with unit).

• Connect sufficient tubing to the unit to allow the unit to be

moved for cleaning and servicing. However, make certain that
the tubing is not pinched or damaged during installation.

• U-Line recommends the use of copper tubing for installation.

On BI-95 and BI-98 models, the water line is inserted through the hole
in the rear of the unit to connect to the solenoid valve in the front
(Figure 5).

Figure 5

UL101

POWER

CORD

WATER LINE

12

30035 User Manual Body.qxd 1/5/05 8:08 AM Page 12