User’s manual – U-Line ICE-MAKER User Manual
Page 52

50
User’s Manual
Problem
Possible Cause
Remedy
The unit is not
Airflow to front grille
Airflow must not be
cold enough (cont.)
blocked
obstructed to front grille.
See INSTALLATION or
CLEANING AND
MAINTENANCE.
Temperature not set
Turn control knob
cold enough
CLOCKWISE to set
temperature colder.
Allow 24 hours for
temperature to stabilize.
The unit is not cold
The door was left open Turn
off the unit to manually
enough (Frost free
causing the evaporator
defrost the evaporator.
units only)
behind the back wall to
See DEFROSTING.
fill with frost preventing
proper air flow and
cooling.
The unit frosts
Unit is manual
Models SP18, 95, 98,
up
defrost model
and Combo 29A and
75A are manual defrost.
Refer to DEFROSTING.
Door gasket not
Adjust door. See
sealing properly
ALIGNING THE DOOR.
High ambient
Defrost unit manually.
temperatures or
See DEFROSTING.
humidity
Water is leaking
Water supply
Tighten fitting. See
out the back
connection leaking
CONNECTING THE
of the unit
WATER SUPPLY.
Ice cubes
Door gasket not
Adjust door. See
sticking together
sealing properly
ALIGNING THE DOOR.
Infrequent use of cubes
Break apart cubes.
Noise during
Copper water supply
Carefully bend tubing
operation
tubing contacting
away from cabinet and
internal components
components.
Certain sounds are
Soft sounds from the fan
normal.
and water/dropping
sounds from the ice maker
will be heard.
Fan blade touching
Remove obstruction.
obstruction (wiring,
foam insulation, etc.)
30035 User Manual Body.qxd 1/5/05 8:08 AM Page 50