Conversion of gas – Tricity Bendix SG 205WL User Manual
Page 23
23
CONVERSION OF GAS
Your cooker is designed to work with propane or
butane, and is convertible for use with natural
gas.
The natural gas conversion kit is available from
your Service Force Centre and must be fitted by
a Registered engineer/ competent person.
For changing the gas type it is necessary to:
• replace the nozzles (hob, oven and grill);
• adjust the minimum level (hob and oven);
• adjust the primary air (oven and grill);
• check the gas connection;
Stick the label supplied with the
replacement nozzles (from the Service Force
Centre) corresponding to the gas type utilized.
S P E C I F I C A T I O N N O Z Z L E S
Table no.1
(Cat : II
2H3+
)
Cons
Burner
Normal
power
(kW)
Simmer
power
(kW)
By-
pass
(mm)
Gas Type
Pressure
(mbar)
Nozzle
diameter
(mm)
m
3
/h g/h
RAPID 2.60
0.72
0.42
Natural Gas
Butane
Propane
20
28-30
37
1.12
0,86
0,86
0.248
-
-
-
189,05
185,68
SEMI-
RAPID
2.00 0.43 0.32
Natural Gas
Butane
Propane
20
28-30
37
0.96
0,71
0,71
0.191
-
-
-
145,43
142,83
AUXILIARY 1.00 0.35 0.29
Natural Gas
Butane
Propane
20
28-30
37
0.70
0,50
0,50
0.093 -
72,71
71,41
OVEN 3.20
1.00
0.46
Natural Gas
Butane
Propane
20
28-30
37
1.30
0,88
0,88
0.305
-
-
-
232,68
228,52
GRILL 1.80
- -
Natural Gas
Butane
Propane
20
28-30
37
1,00
0,67
0,67
0,172
-
-
-
130,88
128,55