background image

Sound of the other

party is broken

during call.

Same symptom

remains even

the station

is replaced.

Immediately after
the calling tone,
the line switches
to cancel, busy,

dial tone, etc.

Same symptom
remains even

the station

is replaced.

Becomes normal

if the station
is replaced.

Adjust the volume control of

station speaker if the room
produces reverberation.

(Lower the volume.)

Increase the gain of MIC AMP.
Replace PCB after checking if

MIC unit is not touching its

case.

One of R-Lines is disconnected.
Fault in photo coupler PC-504

on

LMU.

Fault in MT-547 on LMU or in

the station.

One of the R-Lines is discon-
nected or the station connector

is not connected properly.