8-3.

FAULT IN SPECIFIC STATION ONLY

Find the cause according to the following table if the fault

lies with a specific station only, not with all stations.

CHECK-ITEM

Dialing can not

be made at privacy

off mode.

LMU Lamp is

off.

Specific Lamp

on LMU is

brighter than

normal.

LMU Lamp is
on in normal.

Specific key does

not operate.

Replace the

station and

make sure that

the station

is not faulty.

Calling tone can

not be heard.

Dialing tone can

not be heard on

dialing.

Sound from the

other party can

not be heard.

Same sympton

remains even

if the station
is replaced.

Becomes normal

if the station
is replaced.

Sound is not trans-

mitted to the other

party.

Same sympton

remains even

the station

is replaced.

Becomes normal

if the station

is replaced.

On dialing, noise

is heard by the
called party.

Same sympton

remains even

the station is
replaced.

Becomes normal

if the station
is replaced.

T & R-Lines are shorted.

Fault in the station.

(Replace PCB board.)

Fault in key board switch or

matrix circuitry.

Fault in the dial generator.

(Replace PCB board.)

Short or open in R-Line.

Fault in the demodulation cir-
cuitry on LMU.

(Check LM-380, MT-547.)

Disconnection of R-Line or im-

proper connection of the station

connector.

Fault in MT-547 on LMU.

Station fault.

Short or open in T-Line.

Fault in the modulation cir-

cuitry on LMU.

Fault in MIC circuitry of the
station. (Replace MIC or PCB)

One of T-Lines is disconnected.

Fault in MIC element.
Fault in T-Line of the station.

Low frequency oscillation of

MIC AMP. (Faulty bypass capaci-

tor)

CAUSE

Disconnection of both T & R-Lines.
Guard resistor 330 on LMU is
burned out due to T & R-Lines

short.

-66-