Toshiba RAS-10SKV-A User Manual
Page 64
– 63 –
FILE NO. SVM-07008
11-4-2. Caution at servicing
(1) After servicing, push the [ ] button to return to the normal mode.
(2) After servicing by the check code, turn off breaker of the power supply, and turn on breaker of the power
supply again so that memory in the microcomputer returns the initial status. However, the check codes are
not deleted even if the power supply is turned off because they are stored in the fixed memory.
Table 11-4-1
Block distinction
Operation of diagnosis function
Judgment and action
Check
Block
Check
Cause of operation
Air conditioner
Remarks
code
code
status
Short-circuit or disconnec-
tion of the room
temperature sensor
(TA sensor).
Being out of place,
disconnection, short-circuit,
or migration of heat
exchanger sensor
(TC sensor)
Lock of indoor fan or trouble
on the indoor fan circuit
Trouble on other indoor
P.C. boards
Return serial signal is not
sent to indoor side from
operation started.
(1) Defective wiring of
connecting cable
(2) Operation of
compressor thermo.
Gas shortage
Gas leak
Operation command signal
is not sent to outdoor side.
Operation
continues.
Operation
continues.
All off
Operation
continues.
Operation
continues.
Operation
continues.
Displayed when
error is detected.
Displayed when
error is detected.
Displayed when
error is detected.
Displayed when
error is detected.
Flashes when
trouble is
detected on
return serial
signal, and
normal status
when signal is
reset.
Flashes when
trouble is
detected on
operation
command signal,
and normal status
when signal is
reset.
1. Check the room temp. sensor.
2. When the room temp. sensor is
normal, check P.C. board.
1. Check heat exchanger sensor.
2. When heat exchanger sensor is
normal, check P.C. board.
1. Check P.C. board.
2. When P.C. board is normal, check
the motor.
Replace P.C. board.
1. When the outdoor unit never
operate:
(1) Check connecting cable, and
correct if defective wiring.
(2) Check 25A fuse of inverter
P.C. board
(3) Check 3.15A of inverter
P.C. board.
2. To display [Other] block during
operation, check compressor
thermo. operation and supply gas
(check gas leak also).
3. Unit operates normally during
check.
If Return serial signal does not
stop between
2
and
3
of the
indoor terminal block, replace
inverter P.C. board.
If signal stops between indoor
terminal block
2
and
3
, replace
indoor P.C. board.
If return serial signal does not stop
between indoor terminal block
2
and
3
, replace inverter P.C. board.
If signal stops between indoor
terminal block
2
and
3
, replace
indoor P.C. board.
Indoor
P.C.
board
etc.
Not
displayed
Connec-
ting cable
and serial
signal