beautypg.com

Toshiba RAS-10SKV-A User Manual

Page 35

background image

34

Item

8. ECO

operation

Operation flow and applicable data, etc.

When pressing [ECO] button on the remote controller, a

Economic operation is performed.

This function operates the air conditioner with the difference

between the set and the room temperature as shown in the

following figure.

Description


1) Setting the compressor speed to

Max. aHz, the temperature zone

in which the operation can be

performed with Max. cHz is

gradually widened after 30

minutes passed when starting

ECO operation.

* 12 (DRY max - COOL min) /6 x 5 + COOL min
* 11 (DRY max - COOL min) /6 x 4 + COOL min
* 10 (DRY max - COOL min) /6 x 3 + COOL min

* 9 (DRY max - COOL min) /6 x 2 + COOL min
* 8 (DRY max - COOL min) /6 x 1 + COOL min

30 minutes

A

B

C

A

B

C

Time Compressor

speed

0Hz

A zone

aHz

B zone

a to cHz

C zone

cHz

0

–0.5
–1.0
–1.5
–2.0
–2.5
–3.0
–4.0
–5.0
–6.0
–7.0
–8.0
–9.0

–10.0
–11.0

(Room temp.

Set temp.)

+3.5
+3.0
+2.5

+1.5

+1.0

TSC

-1.0

-2.0

+5.5

1H

2H

11
10

7
6

5

4
3

2

1

OFF

Dry Max

*12
*11

*9

*8

*10

TA

+6.0

+6.5

3H

4H

+5.0

+4.5

+4.0

+2.0

+0.5

-0.5

12

9
8

Time

Zone Frequency

Min

Hz

Fan speed depend on presetting and can change every speed.


Hz 10SKVR-E, 10SKV-A

Cool min

Dry max

22

32

Hz

10SKV-E

10SKV-A

a

22

c

52

1) The control target temperature

increase 0.5ºC per hour up to 2ºC
starting from the set temperature

when ECONO has been received.

2

) The indoor fan speed is depend

on presetting and can change
every speed after setting ECO

operation.


2

) The indoor fan speed is depend

on presetting and can change
every speed after setting ECO

operation.

FILE NO. SVM-07008


3

) The compressor speed is

controlled as shown in the left

figure.

This manual is related to the following products: