3. Names and functions of main parts

Connector terminal (removal side)

• Wire size (shielded twisted-pair cable recommended)

Bare wire (without stick lug) : 0.2~1.5mm

2

Phoenix Contact TWIN terminal : (wire size below)

× 2

Part number: AI-TWIN2

×0.5-8WH, AI-TWIN2×0.75-8GY, AI-TWIN2×1-8RD, AI-

TWIN2

×1.5-8BK

• Removable terminal block

COMBICON terminal blocks such as the Phoenix Contact TMSTBP series that allows
signal branching can be used in place of included terminal.

R R T T S S
X X X X G H
A B A B I
E
L
D

SW

INVERTER 1

INVERTER 2

RS485
OPTION UNIT

Switch for communication speed

& Termination resistor setting
(Note) Set the switch before power on

1 2 3 4

(Back side of the UNIT)

OFF (OPEN)

ON

(Front side of the UNIT)

(1) Communication speed setting (SW1, 2)

Setting
SW1

SW2

Baud
rate

OFF

OFF

1200

ON

OFF

2400

OFF

ON

4800

ON

ON

9600

Set the communication speed to the
same as ASD’s (F800).

(2) Terminating resistor setting (SW3, 4)

SW3-ON : Connecting receiving side
SW4-ON : Connecting transmitting side

Connect the terminating resistor to both
end of system.

Receiving
terminal
RXA, RXB

Transmitting
terminal
TXA, TXB

Signal common
terminal
SG

Shield
terminal
SHIELD

Connector
terminal
(socket side)
Insert removal
terminal block

Communication connector: INVERTER 1, INVERTER 2

Connect with the communication connector CN1 of the
ASD with communication cable.

7mm

Connector terminal
(removal side)
Insert socket
terminal block

M3

Terminal pitch : 5.08mm