Selection
Procedure

CAB-PRC001-EN

6

Note: Please contact your local Trane sales representative for buildable digit combinations.

Model Number
Description

Digit 27 — Main Control Valve
0 = None
A = 2-Way, 2-Position, NO (25 psig)
B = 3-Way, 2-Position, NO (30 psig)
C = 2-Way, 2-Position, NC (25 psig)
D = 3-Way, 2-Position, NC (15 psig)
E = 2-Way, 2-Position, NO (50 psig)
F = 3-Way, 2-Position, NO (50 psig)
G = 2-Way, 2-Position, NC (50 psig)
H = 3-Way, 2-Position, NC (50 psig)
J = 2-Way, Modulating, 0.7 Cv (50 psig)*
K = 3-Way, Modulating, 0.7 Cv (50 psig)*
L = 2-Way, Modulating, 1.5 Cv (50 psig)*
M= 3-Way, Modulating, 1.5 Cv (50 psig)*
N = 2-Way, Modulating, 2.5 Cv (50 psig)*
P = 3-Way, Modulating, 2.5 Cv (50 psig)*
Q = 2-Way, Modulating, 4.0 Cv (50 psig)*
R = 3-Way, Modulating, 4.0 Cv (50 psig)*
X = Field-supplied, NO
Y = Field-supplied, NC
Z = Field-Supplied 3-Wire Modulating

Digit 28 — Not Used
0 = None

Digit 29 — Piping Packages
0 = None
A = Basic Ball Valve Supply and Return
B = Basic Ball Valve Supply/Manual

Circuit Setter

C = Basic Ball Valve Supply and Return

with Auto Circuit Setter

D = Deluxe Ball Valve Supply and Return
E = Deluxe Ball Valve Supply/Manual

Circuit Setter

F = Deluxe Ball Valve Supply and Return

with Auto Circuit Setter

Digit 30 — Control Type
A = Fan Speed Switch
E = Tracer ZN.010
F = Tracer ZN.510
G = Tracer ZN.520

Digit 31 — Control Option
D = Unit Mounted Fan Speed Switch
K = Wall Mounted Fan Speed Switch
V = Unit Mounted Fan Speed Switch w/
Setpoint Dial
W = Wall Mounted Fan Speed Switch w/
Setpoint Dial
X = Unit Mounted Fan Speed Switch w/
Wall Mounted Setpoint Dial
Y = Unit Mounted Fan Speed Switch &
Wall Mounted Setpoint Dial W/ Comm.
Z = Unit Mounted Fan Speed Switch,
On/Cancel, Setpoint Dial W/ Comm.
1 = Wall Mounted On/Cancel W/ Comm.
2 = Wall Mounted Fan Speed Switch,
Setpoint Dial, On/Cancel W/ Comm.

Digit 32 —Not Used
0 = None

Digits 33, 34 —Future Control Functions
0 = None

Digit 35 — Control Function #3
0 = None

Digit 36 — Control Function #4
0 = None

Digit 37 — Control Function #5
0 = None
2 = Fan Status Sensor

Digit 38 — Control Function 6
0 = None
2 = Filter Status Sensor

Digit 39 — Projection Panels and
Falsebacks
0 = None
A=

5

/

8

” Standard Recessed Panel

(Vertical Recessed Units Only)

B = 2” Projection Panel
C = 2.5” Projection Panel
D= 3” Projection Panel L =2”Falseback
E = 3.5” Projection Panel M=3” Falseback
F = 4” Projection Panel N =4” Falseback
G =

4.5” Projection

Panel

P =5” Falseback

H= 5” Projection Panel Q =6” Falseback
J = 5.5” Projection Panel R =7” Falseback
K = 6” Projection Panel T =8” Falseback

Digit 40 — Main Autoflow GPM
A = 0.5

G = 3.0

N = 7.0

B = 0.75

H = 3.5

P = 8.0

C = 1.0

J = 4.0

Q = 9.0

D = 1.5

K = 4.5

R = 10.0

E = 2.0

L = 5.0

T = 11.0

F = 2.5

M= 6.0

U = 12.0

Digit 41 — Not Used

Digit 42 — Subbases
0 = None
A = 2” Subbase

D =5” Subbase

B = 3” Subbase

E =6” Subbase

C = 4” Subbase

F =7” Subbase

Digit 43 — Recessed Flange
0 = None
A = Recessed Flange

Digit 44 — Wall Boxes
0 = None
A = Anodized Wall Box