Table ED-2. Free Discharge Motors on Units with Two-Row, Electric, or Steam Coils

115 Volt

208-230 Volt

277-480 Volt

RPM

FC

FLA

HP (kW)

FLA

HP (kW)

FLA

HP (kW)

H

M

L

02

0.6

.03 (.02)

0.3

.03 (.02)

0.2

.03 (.02)

980

840

655

03

0.7

.04 (.02)

0.4

.04 (.02)

0.3

.04 (.02)

980

780

580

04

0.9

.05 (.04)

0.5

.05 (.04)

0.4

.05 (.04)

1050

780

580

06

1.2

.07 (.05)

0.6

.07 (.05)

0.5

.07 (.05)

1030

780

580

08

1.4

.12 (.09)

0.9

.12 (.09)

0.6

.12 (.09)

1080

800

600

10

0.9

1.2

.05 (.04)

.07 (.05)

0.5

0.6

.05 (.04) .07 (.05)

0.4

0.5

.05 (.04) .07 (.05)

1050

780

580

1030

780

580

12

0.9

1.4

.05 (.04)

.12 (.09)

0.5

0.9

.05 (.04) .12 (.09)

0.4

0.6

.05 (.04) .12 (.09)

1050

780

580

108

800

600

Table ED-3. High Static Motors on Units with Two-Row, Electric, or Steam Coils

115 Volt

208-230 Volt

277- 480 Volt

RPM

FC

FLA

HP (kW)

FLA

HP (kW)

FLA

HP (kW)

H

M

L

02

1.1

.07 (.05)

0.6

.07 (.05)

0.5

.07 (.05)

1480

1110

865

03

1.4

.08 (.06)

0.7

.08 (.06)

0.6

.08 (.06)

1400

1175

860

04

1.6

.10 (.07)

0.8

.10 (.07)

0.7

.10 (.07)

1475

1315

1070

06

2.6

.16 (.12)

1.2

.16 (.12)

1.0

.16 (.12)

1400

1070

855

08

3.4

.24 (.18)

1.4

.24 (.18)

1.1

.24 (.18)

1475

1285

975

10

1.6

2.6

.10 (.07)

.16 (.12)

0.8

1.2

.10 (.07) .16 (.12)

0.7

1.0

.10 (.07) .16 (.12)

1475

1315

1070

1400

1070

855

12

1.6

3.4

.10 (.07)

.24 (.18)

0.5

0.9

.10 (.07) .24 (.18)

0.7

1.1

.10 (.12) .24 (.18)

1475

1315

1240

1475

1285

975

Table ED-4. Free Discharge Motors on Units with Three and Four-Row Coils

115 Volt

208-230 Volt

277-480 Volt

RPM

FC

FLA

HP (kW)

FLA

HP (kW)

FLA

HP (kW)

H

M

L

02

0.6

.03 (.02)

0.3

.03 (.02)

0.2

.03 (.02)

980

840

655

03

0.8

.05 (.04)

0.5

.05 (.04)

0.4

.05 (.04)

1080

800

600

04

1.0

.06 (.04)

0.6

.06 (.04)

0.5

.06 (.04)

1080

800

600

06

1.4

.12 (.09)

0.9

.12 (.09)

0.6

.12 (.09)

1080

800

600

08

1.7

.13 (.10)

1.0

.13 (.10)

0.8

.13 (.10)

1080

800

600

10

1.0

1.4

.06 (.04)

.12 (.09)

0.6

0.9

.06 (.04) .12 (.09)

0.5

0.6

.06 (.04) .12 (.09)

1080

800

600

1080

800

600

12

1.0

1.7

.06 (.04)

.13 (.10)

0.6

1.0

.06 (.04) .13 (.10)

0.5

0.8

.06 (.04) .13 (.10)

1080

800

600

1080

800

600

Table ED-5. High Static Motors on Units with Three and Four-Row Coils

115 Volt

208-230 Volt

277-480 Volt

RPM

FC

FLA

HP (kW)

FLA

HP (kW)

FLA

HP (kW)

H

M

L

02

1.1

.07 (.05)

0.6

.07 (.05)

0.5

.07 (.05)

1480

1110

865

03

1.3

.08 (.06)

0.7

.08 (.06)

0.5

.08 (.06)

1500

1355

1110

04

2.1

.13 (.10)

0.9

.13 (.10)

0.7

.13 (.10)

1580

1375

1240

06

3.4

.24 (.18)

1.4

.24 (.18)

1.1

.24 (.18)

1475

1285

975

08

3.4

.24 (.18)

1.4

.24 (.18)

1.1

.24 (.18)

1475

1285

975

10

2.1

3.4

.13 (.10)

.24 (.18)

0.9

1.4

.13 (.10) .24 (.18)

0.7

1.1

.13 (.10) .24 (.18)

1580

1375

1240

1475

1285

975

12

2.1

3.4

.13 (.10)

.24 (.18)

0.9

1.4

.13 (.10) .24 (.18)

0.7

1.1

.13 (.10 ) .24 (.18)

1580

1375

1240

1475

1285

975

Note: