beautypg.com

Cable specifications, Continued), Twisted-pair copper cable – Transition Networks SSDTF1014-100 User Manual

Page 3: Dry-contact relay, Switch-selectable configurations, Switch-selectable functions

background image

CABLE SPECIFICATIONS

(continued)

Twisted-Pair Copper Cable

Twisted pair connection requires two active pairs. The two active pairs
in a T1/E1 network are pins 1 & 2 and pins 4 & 5. Use only dedicated
wire pairs (such as blue/white & white/blue, orange/white &
white/orange) for the active pins.

Category 3 or better twisted-pair copper wire is required. Either shielded
twisted-pair (STP) or unshielded twisted-pair (UTP) can be used.

T1:

Gauge

24 to 22 AWG

Attenuation

2.6 dB/100 meters @ 1.0 MHz

Differential Characteristic Impedance

100

±10%

E1:

Gauge

24 to 22 AWG

Attenuation

2.6 dB/100 meters @ 1.0 MHz

Differential Characteristic Impedance

120

±10%

Dry-Contact Relay

RJ-45 dry-contact relay opens if power, signal detect/copper or signal
detect/fiber are lost.

Operational rating on pins 3 and 6: 0-30VDC maximum 1A

Switch-Selectable Configurations

T1 COPPER RJ-45

Configured as either "long haul" or “short haul” on 100 ohm cable, with
a variety of selectable distance settings.

E1 COPPER RJ-45

Configured as either "long haul" or “short haul” on 120 ohm cable.

STRAIGHT-THROUGH/CROSSOVER RJ-45

Allows straight-through cable to be used where crossover-configuration
cable is required.

Switch-Selectable Functions

LOOPBACK TEST FUNCTION

A loopback switch facilitates installation and network debug procedures.
The path for the SSDTF10xx loopback is shown:

TRANSMIT ALL ONES FUNCTION

A selectable Transmit All Ones switch on the fiber interface and on the
twisted-pair interface allows for insertion of an “all ones” pattern on that
interface when signal detect is lost, which creates an alarm condition at
the equipment connected to the interface.

RJ-45

Relay

3

6

Fiber

TP

TP

This manual is related to the following products: