Ssdtf10xx in the network, Technical specifications – Transition Networks SSDTF1014-100 User Manual
Page 2
SSDTF10xx IN THE NETWORK
NOTE: THE SSDTF10xx REQUIRES A CSU BETWEEN THE MEDIA
CONVERTER AND THE PUBLIC TELEPHONE NETWORK.
NOTE: T1/E1 MEDIA CONVERTERS MUST BE USED IN PAIRS. A TRANSITION
Networks SSDTF10xx stand-alone media converter can be used with another
SSDTF10xx stand-alone media converter, with a CSDTF10xx chassis media
converter, or with a previous model TRANSITION Networks T1/E1 media
converter, such as a C/T1E1-CF-01 or a T1E1-CF-01.
Features
•
Media converter is framing independent (as ESF vs D4) and supports all
common line codes, (AMI, B8ZS, HDB3).
•
Dry relay contacts allow media converter to be tied into separate alarm
circuit
•
All Ones Insertion (AIS) on loss of signal at copper and/or fiber interface.
TECHNICAL SPECIFICATIONS
Standards
Emissions: CISPR A
T1/E1 Physical Layer: ITU-T, ANSI, AT&T, ETSI
Dimensions
2.9" x 4.8" x 1.4"
Weight
8 oz (approximate)
Power Source
7.5-15.9 VDC AC Adapter
Power Consumption
5 watts
Power Supply Requirements Replace power supply with only the equivalent
input rating (see below) and output rating (regulated 9VDC at 550 mA).
TN PN
Requirement
Location
25034 or 3525
240 volts, 50 hertz
United Kingdom
25034 or 3525
230 volts, 50 hertz
Europe
3518
120 volts, 60 hertz
USA/Canada/Mexico
3514
100 volts, 50-60 hertz Japan
25034 or 3525
240 volts, 50 hertz
Australia
Environment
Typical Operating Temperature*: 0°
to
50°C (32°
to
122°F )
Storage Temperature:
-20°
to
85°C (-4°
to
185°F)
Humidity
10-90%, non condensing
Altitude
0-10,000 feet
Warranty
Lifetime
DECLARATION OF CONFORMITY
Name of Mfg:
Transition Networks
6475 City West Parkway, Minneapolis MN 55344 USA
Model:
SSDTF10xx Series Copper-to-Fiber Media Converter
Part Number:
SSDTF1011-100, SSDTF1012-100, SSDTF1013-100,
SSDTF1022-100
Regulation:
EMC Directive 89/336/EEC
Purpose: To declare that the SSDTF10xx to which this declaration refers is in
conformity with the following standards.
EN 55022:1994; EN 55024:1998; FCC Part 15 Class A; EN 60950 A4:1997; UL 1950
I, the undersigned, hereby declare that the equipment specified above conforms to the
above Directive(s) and Standard(s).
_January 8, 2001_____
Stephen Anderson, Vice-President of Engineering
Date
T1 Network Extension
CSU
M10
ASTER
RX
TX
LNK
PWR
RESET
DB-9
12C
12C-1
TERM
INIT
CETTF100
CFETF110
LKF
PWR
RXF
RXC
LKC
SPD
PWR
FRX
CRX
FLNK
CLNK
RX
TX
10/100TX
RX
TX
10/100SX
CFETF100
SPD
PWR
FRX
CRX
FLNK
CLNK
RX
TX
100BASE-FX
10BASE-T
10BASE-FL
SPD
PWR
FRX
CRX
FLNK
CLNK
RX
TX
100BASE-FX