beautypg.com

Ssdtf10xx in the network, Technical specifications – Transition Networks SSDTF1014-100 User Manual

Page 2

background image

SSDTF10xx IN THE NETWORK

NOTE: THE SSDTF10xx REQUIRES A CSU BETWEEN THE MEDIA
CONVERTER AND THE PUBLIC TELEPHONE NETWORK.

NOTE: T1/E1 MEDIA CONVERTERS MUST BE USED IN PAIRS. A TRANSITION
Networks SSDTF10xx stand-alone media converter can be used with another
SSDTF10xx stand-alone media converter, with a CSDTF10xx chassis media
converter, or with a previous model TRANSITION Networks T1/E1 media
converter, such as a C/T1E1-CF-01 or a T1E1-CF-01.

Features

Media converter is framing independent (as ESF vs D4) and supports all
common line codes, (AMI, B8ZS, HDB3).

Dry relay contacts allow media converter to be tied into separate alarm
circuit

All Ones Insertion (AIS) on loss of signal at copper and/or fiber interface.

TECHNICAL SPECIFICATIONS

Standards

Emissions: CISPR A

T1/E1 Physical Layer: ITU-T, ANSI, AT&T, ETSI

Dimensions

2.9" x 4.8" x 1.4"

Weight

8 oz (approximate)

Power Source

7.5-15.9 VDC AC Adapter

Power Consumption

5 watts

Power Supply Requirements Replace power supply with only the equivalent
input rating (see below) and output rating (regulated 9VDC at 550 mA).

TN PN

Requirement

Location

25034 or 3525

240 volts, 50 hertz

United Kingdom

25034 or 3525

230 volts, 50 hertz

Europe

3518

120 volts, 60 hertz

USA/Canada/Mexico

3514

100 volts, 50-60 hertz Japan

25034 or 3525

240 volts, 50 hertz

Australia

Environment

Typical Operating Temperature*: 0°

to

50°C (32°

to

122°F )

Storage Temperature:

-20°

to

85°C (-4°

to

185°F)

Humidity

10-90%, non condensing

Altitude

0-10,000 feet

Warranty

Lifetime

DECLARATION OF CONFORMITY

Name of Mfg:

Transition Networks
6475 City West Parkway, Minneapolis MN 55344 USA

Model:

SSDTF10xx Series Copper-to-Fiber Media Converter

Part Number:

SSDTF1011-100, SSDTF1012-100, SSDTF1013-100,
SSDTF1022-100

Regulation:

EMC Directive 89/336/EEC

Purpose: To declare that the SSDTF10xx to which this declaration refers is in

conformity with the following standards.

EN 55022:1994; EN 55024:1998; FCC Part 15 Class A; EN 60950 A4:1997; UL 1950

I, the undersigned, hereby declare that the equipment specified above conforms to the

above Directive(s) and Standard(s).

_January 8, 2001_____

Stephen Anderson, Vice-President of Engineering

Date

T1 Network Extension

CSU

M10
ASTER

RX

TX

LNK

PWR

RESET

DB-9

12C

12C-1

TERM

INIT

CETTF100

CFETF110

LKF

PWR

RXF

RXC

LKC

SPD

PWR

FRX

CRX

FLNK

CLNK

RX

TX

10/100TX

RX

TX

10/100SX

CFETF100

SPD

PWR

FRX

CRX

FLNK

CLNK

RX

TX
100BASE-FX

10BASE-T

10BASE-FL

SPD

PWR

FRX

CRX

FLNK

CLNK

RX

TX
100BASE-FX

This manual is related to the following products: