beautypg.com

2. operation data – Toshiba RAS-10YKV-E User Manual

Page 20

background image

– 20 –

6-2. Operation Data

NOTES :

(1) Measure surface temperature of heat exchanger pipe around center of heat exchanger path U bent.

(Thermistor themometer)

(2) Connecting piping condition : 5 m

Temperature

condition (°C)

Heat exchanger

pipe temp.

Indoor

Outdoor

Model name

Standard

pressure

P (MPa)

T1 (°C)

T2 (°C)

Indoor fan

mode

Outdoor fan

mode

Compressor

revolution

(rps)

10YKV-E

0,8 to 1,0

9 to 11

42 to 44

High

High

56

27/19

35/–

13YKV-E

0,8 to 1,0

8 to 10

46 to 48

High

High

85

Temperature

condition (°C)

Heat exchanger

pipe temp.

Indoor

Outdoor

Model name

Standard

pressure

P (MPa)

T1 (°C)

T2 (°C)

Indoor fan

mode

Outdoor fan

mode

Compressor

revolution

(rps)

10YKV-E

3,5 to 3,7

42 to 44

2 to 4

High

High

70

20/–

7/6

13YKV-E

2,5 to 2,7

50 to 52

0 to 3

High

High

97

This manual is related to the following products: