Tannoy V12 HP User Manual
Page 16

13.3 Biamp System Parameters
Parameter
Unit/Name
Low Section
High Section
Gain
(dB) 0
-1.0
Delay
(ms) 0.167 0
Polarity
Positive
Positive
HPF Ä
Freq (Hz)
42.5
1680
Slope (dB/oct)
24
24
Filter Shape
Butterworth
Linkwitz Riley
LPF
Freq (Hz)
1470
Thru
Slope (dB/oct)
24
NA
Filter Shape
Linkwitz Riley
NA
Freq (Hz)
62.5
2720
Level (dB)
+7
-4
Type Parametric
Parametric
PEQ 1 Ä
Q / Bandwidth 2.0 / 0.5000
2.1 / 0.4719
Freq (Hz)
454
10700
Level (dB)
-3
+5
Type Parametric
Parametric
PEQ 2
Q / Bandwidth 1.7 / 0.5946
1.9 / 0.5297
Freq (Hz)
642
15100
Level (dB)
-2
+3
Type
Parametric
2.4 / 0.4204
PEQ 3
Q / Bandwidth 4.0 / 0.2500
NA
Freq (Hz)
1010
NA
Level (dB)
+6
NA
Type Parametric
NA
PEQ 4
Q / Bandwidth 4.0 / 0.2500
NA
Freq (Hz)
NA
NA
Level (dB)
NA
NA
Type NA
NA
PEQ 5
Q / Bandwidth NA
NA
Ä
Note : When using the V12HP with subs, set HPF on LF section @ 80 – 110Hz
(24dB/oct LR) and omit PEQ1 (on LF only)
PEQ 1 (on LF only) may also be omitted when using the V12HP as a floor monitor.