beautypg.com

Tannoy V12 HP User Manual

Page 15

background image

13.2 Passive System Parameters (optional)

With the vast array of digital loudspeaker management systems available it is inevitable that the user
may opt to use a controller other than the TX2 & TDX2 as part of a large scale integrated system. In

passive mode the V12HP has been designed to need no external equalisation to overcome system

limitations. If the V12HP is to be used alone with additional bass enhancement required and have

the frequency response limits tighter than +/- 3dB as stated in section 11, then apply the

parameters in the table below for optimised performance:-



Parameter Unit/Name


Gain

(dB) User

definable

Delay

(ms) User

definable

Polarity

Positive


HPF Ä

Freq (Hz)

42.5

Slope (dB/oct)

24

Filter Shape

Butterworth

LPF

Freq (Hz)

Thru

Slope (dB/oct)

NA

Filter Shape

NA

Freq (Hz)

62.5

Level (dB)

+7

Type Parametric

PEQ 1 Ä

Q / Bandwidth

2.5 / 0.3969

Freq (Hz)

680

Level (dB)

-3.5

Type Parametric

PEQ 2

Q / Bandwidth

1 / 1.000

Freq (Hz)

1410

Level (dB)

-1

Type Parametric

PEQ 3

Q / Bandwidth

4 / 0.2500

Freq (Hz)

7130

Level (dB)

-2

Type Parametric

PEQ 4

Q / Bandwidth

2 / 0.500

Freq (Hz)

NA

Level (dB)

NA

Type NA

PEQ 5

Q / Bandwidth

NA


Ä

Note : When using the V12HP with subs, set HPF @ 80 – 110Hz

(24dB/oct LR) and omit PEQ1.

PEQ 1 may also be omitted when using the V12HP as a floor monitor.