IF-CB/DM

CobraNet Interface Card

DUAL LINK:
This shows the network connection method.

Prefer

Primary

(default setting):

The Primary network has priority. If the Primary network
connection is lost, the mixer automatically switches to
the Secondary network, and reconnects to the Primary
network when it recovers.

Always

Primary

:

Only uses the Primary network.

Always

Secondary

:

Only uses the Secondary network.

Auto

Switch

:

Uses the Primary network at start-up. If the Primary
network connection is lost, it switches to the Secondary
network, and continues using the Secondary network
even if the Primary network recovers. If the Secondary
network connection is lost, it switches back to the
Primary network.

NAME:
This shows the name of the installed IF-CB/DM card.

LATENCY:
This shows the current latency setting.

BITS:
This shows the current bit-rate setting.

SYSTEM

ª

This section shows information about the system.

F/W VER:
This shows the IF-CB/DM firmware version.

ERRORS:
This shows the number of errors that have occurred.

LOAD:
This shows the network load.

DM-3200/4800 settings

Setting the clock

1 Press the PROJECT key to open the CLOCK

screen where you can set the clock source. (See the
“Clock setting” section of chapter 3 of the DM-3200/
DM-4800 User’s Manual.)

2 Set the Fs MODE to 48k, and in the CLOCK SE-

LECT area, select the SLOT where the IF-CB/DM
card is installed. This enables stable operation even
when switching between conductor and performer.

Input settings (input routing)

Make input settings on the INPUT page of the DM-3200/
DM-4800 ROUTING screen.

DM-3200 INPUT page

1 Use the POD 4 knob to select the input source group.

Input source groups are shown in the SOURCE SE-
LECT list at the lower right of the screen.

2 Use the POD 3 knob to select the input source rout-

ing destination layer. Routing destination groups are
shown in the LAYER SELECT list at the upper right
of the screen.

3 Use the cursor keys to select the source field, and use

the JOG/DATA dial to select the input source.

4 After making the selection, press the ENTER key to

confirm it.

Output settings (output routing)

Make output settings using the OUTPUT SLOT page of the
DM-3200/DM-4800 ROUTING screen.

DM-3200 OUTPUT SLOT page

TASCAM IF-CB/DM