MIU9.6FPD Installation, Operation & Diagnostics

April 25, 1998

Page 13


11. DIAGNOSTICS

The following pages provide hardware techniques for diagnosing
communication problems and thereby isolating the problem at the local
modem, the remote modem or the interconnecting line.


(a) LOCAL ANALOG LOOPBACK (Figure 2)

Requires a loop back cable with a built-in circuit for line loss to
simulate a typical leased line condition (See Figure 3).

Connect the loop back cable to the RJ11 connector on the modem
under test.

Set Dip Switches as follows…

Switch 7 = OFF

4-Wire

Switch 9 = ON

Soft Carrier Turn Off Enabled

Switch 1 = ON

Transmit (TxA) Signal Level = 0dBm

Switch 3 = ON

Receive (RxA) Signal Level = –33dBm

Switch 6 = OFF

Switched Carrier

Switch 4&5 = ON

RTS/CTS Delay = 50ms


Test 1: RTS/CTS Analog Control

Set RTS “ON” and check that CD (Carrier Detect) turns
“ON”.


Turn RTS “OFF” and ensure that CD turns “OFF”


With RTS “ON”, run a test message at TxD and verify that
the same message is received at RxD with no data errors.


Test 2: Transmit Signal Power & Receive Levels

Set Dip Switch 1 OFF (TxA = -10dBm)

CD will be OFF.

Change Dip Switch 1 to ON (TxA = 0dBm)

CD should now be ON.