Data Sheet: Veta

iHA48040A033V*, 3.3V/40A Output Half Brick Series

©2007 TDK Innoveta Inc.
iHA Datasheet 040207

'

(877) 498-0099

10/17

Thermal Performance:

10

20

30

40

25

35

45

55

65

75

85

95

105

115

Ambient Temperature (

o

C)

Output Current (A)

NC 0.3 m/s (60 LFM)

0.5 m/s (100 LFM)

1.0 m/s (200 LFM)

1.5 m/s (300 LFM)

IMS LIMIT

iHA48040A033V-001 maximum output current vs.
ambient temperature at nominal input voltage for airflow
rates natural convection 0.3 m/s (60lfm) to 3.0m/s
(600lfm) with airflow from output to input.


10

20

30

40

25

35

45

55

65

75

85

95

105

115

Ambient Temperature (

o

C)

Output Current (A)

NC 0.3 m/s (60 LFM)

0.5 m/s (100 LFM)

1.0 m/s (200 LFM)

1.5 m/s (300 LFM)

2.0 m/s (400 LFM)

IMS LIMIT

0.5

1.0

1.5

2.0

2.5

3.0

3.5

4.0

4.5

5.0

0

0.5

1

1.5

2

2.5

3

Airflow, m/s

Case to Ambient Thermal Resistance,

Θ

CA

,

o

C/W

NO HS

1/4" HS

1/2" HS

1" HS

iHA48040A033V-001 maximum output current vs.
ambient temperature at nominal input voltage for airflow
rates natural convection 0.3 m/s (60lfm) to 3.0m/s
(600lfm with airflow from input to output.

iHA48040A033V-001 Case to Ambient Thermal
Resistance vs. Airflow rate