TANDBERG 8000 MXP User Manual
Page 29
Installation
15
IMPORTANT!
To allow the Plasma Monitors to be switched on/off by the system, they must be set to Power
Save Mode:
Press MENU on the Plasma Remote Control
Select
SETUP
Set POWER MANAGEMENT: ON
Press MENU to remove the menu.
The SIGNAL FORMAT has to be changed to PC AUTO. Press MENU on the Plasma Remote
Control:
Select SET UP
Set SIGNAL FORMAT to PC AUTO
If SIGNAL FORMAT is not present, make sure that Codec Output is set to XGA by doing the
following, using the TANDBERG remote control:
Select ‘Control Panel - Administrator Settings - General - Screen Settings’.
Set VGA Out Quality to XGA 1024x768
Press 'Save' when done
Make sure to reset the VGA out Quality to Default after setting the SIGNAL FORMAT
to PC AUTO on Plasma Monitor.
Note that the following steps concerning monitor adjustment are important to avoid
burn in on the plasma screen.
Press MENU on the Plasma Remote Control
Select
OPTION
Set ORBITER: ON
Set MASK CONTROL: ON
Press MENU to remove the menu.
The Orbiter will move the pixels 1 position vertically or horizontally every 8 minutes.
The Mask control will prevent burn in when using picture formats not filling the
whole screen.
The Pioneer menu-buttons are located on the right short-side of the monitor.
Securing the cables
It is important that the wires are secured inside the base so that they don’t get in the way of the
covers, which are to be screwed on to the back.
Attaching the back covers Screw the two back covers on to the base. The lower of the two covers
should be attached first.