168


Signal levels -
line level inputs

Clipping level

Nominal level

Input menu level
settings

Vpp

dBu

dBu

0.0 dB

15.5 Vpp

17.0 dBu

-1.0 dBu

1.5 dB

13.0 Vpp

15.5 dBu

-2.5 dBu

3.0 dB

11.0 Vpp

14.0 dBu

-4.0 dBu

4.5 dB

9.2 Vpp

12.5 dBu

-5.5 dBu

6.0 dB

7.8 Vpp

11.0 dBu

-7.0 dBu

7.5 dB

6.5 Vpp

9.5 dBu

-8.5 dBu

9.0 dB

5.5 Vpp

8.0 dBu

-10.0 dBu

10.5 dB

4.6 Vpp

6.5 dBu

-11.5 dBu

12.0 dB

3.9 Vpp

5.0 dBu

-13.0 dBu

13.5 dB

3.3 Vpp

3.5 dBu

-14.5 dBu

15.0 dB

2.8 Vpp

2.0 dBu

-16.0 dBu

16.5 dB

2.3 Vpp

0.5 dBu

-17.5 dBu

18.0 dB

2.0 Vpp

-1.0 dBu

-19.0 dBu

19.5 dB

1.6 Vpp

-2.5 dBu

-20.5 dBu

21.0 dB

1.4 Vpp

-4.0 dBu

-22.0 dBu

22.5 dB

1.2 Vpp

-5.5 dBu

-23.5 dBu

Table2: Signal Levels - Line level inputs

Note that for the dBu value for input clipping level and absolute max output level, a sine waveform
is assumed. If numbers in dBV are required, dBV value is 2.2 dB lower than the dBu value, e.q. -
10 dBu equals -12.2 dBV

Please see

Interfaces

for details on the audio connectors.