beautypg.com

Installation instructions – Thermador CGX365 User Manual

Page 22

background image

IMPORTANT SAFETY INSTRUCTIONS

Installation must conform with local codes or, in the
absence of local codes, with the National Fuel Gas
Code, ANSI Z223.1.

The appliance must be electrically grounded in
accordance with local codes or, in the absence of
local codes, with the National Electrical Code,
ANSI/NFPA 70-1990. (In Canada, installation must
be in accordance with the CAN 1-B149.1 and .2
Installation Codes for Gas Burning Appliances and/
or local codes.)

This appliance has been tested in accordance with
ANS Z21.1 - 1996, Standard for Household Cooking
Appliances (USA) and in accordance with CAN1.1-
M81 Interim Reqt #58 Domestic Gas Cooktops
(CANADA).

WARNING: Improper installation, adjustment,
alteration, service or maintenance can cause
injury or property damage. Refer to this manual.
For assistance or additional information consult
a qualified installer, authorized service agency,
manufacturer or the gas supplier.

This appliance is equipped with an intermittent/
interrupted ignition device.

The cooktop should be used in conjunction with a
suitable ventilation system. Either a Thermador
overhead or down-draft system is suggested.

INSTALLATION INSTRUCTIONS

GLASS CERAMIC GAS & GLASS CERAMIC DUAL GAS AND ELECTRICS COOKTOPS

30" MODELS: CGX304U

36" MODELS: CGX365U / CD365U

45" MODELS: CGX456U / CD456U

PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING

IMPORTANT: Save these instructions for the local electrical inspector’s use.

INSTALLER: Please leave these Installation Instructions with this unit for the owner.

OWNER: Please retain these instructions for future reference.

TABLE OF CONTENTS

Safety Instructions ....................................................................... 20
Power Requirements and Grounding ..................................... 20
Gas Pressure and Propane Installation ................................... 20
Cabinet Considerations and Cutout ................................. 21-22
Installing the Cooktop .......................................................... 22-23
Connecting Gas ........................................................................... 23
Connecting Electrical Supply ..................................................... 24
Final Check .................................................................................... 24
Before First Use ........................................................................... 24
Warranty ....................................................................................... 25

Page 20

!

!

POWER REQUIREMENTS & GROUNDING
CGX MODELS:

Power Supply: 120 VAC, 15 or 20 Amp. Circuit, 50/60 Hz.
2-wire grounded outlet. For appliance rating See back cover.

This appliance is factory-equipped with a 5-foot power
supply cord with a 3-prong grounding plug (with polarized
parallel blades). THE THIRD GROUND PRONG
SHOULD NOT, UNDER ANY CIRCUM–
STANCES, BE CUT OR REMOVED.
IT MUST BE
PLUGGED INTO A MATING GROUNDING TYPE
RECEPTACLE, CON-NECTED TO A CORRECTLY
POLARIZED 120 VOLT CIRCUIT. A separate circuit is
recommended. If there is any doubt as to whether the
wall receptacle is properly grounded, the customer
should have it checked by a qualified electrician.

WARNING: Before you plug in electrical
cord, be sure all controls are in the OFF position.

POWER REQUIREMENTS & GROUNDING CD
MODELS:
Power Supply:
120 /208 VAC, 15 or 20 Amp. Circuit,
50/60 Hz., 3 wire. 120/240 VAC, 20 Amp. Circuit, 50/60
Hz. 3-wire grounded outlet. For appliance rating, see
back cover. Install junction box (not furnished) below
countertop within 3 feet of flexible conduit (supplied)
located at center rear of cooktop. Junction box must be
accessible from front of cabinet. If cooktop is installed
over an oven, see oven installation instructions.

Supply Pressure
Natural Gas - 6 inches water column minimum.
Propane Gas - 11 inches water column minimum.

Propane Gas Installation
The propane gas tank must be equipped with its own
high pressure regulator in addition to the pressure
regulator supplied with this unit. The maximum gas
pressure to this appliance is not to exceed 14.0 inches
water column from the propane gas tank regulator.

The cooktop is shipped from the factory for use with
natural gas. For use with LP, conversion kit Model
NLPKIT5, Service Part No. 35-00-622, must be purchased
separately. A qualified technican or installer must do
the conversion.

This manual is related to the following products: