Toshiba TEC SL-9000 series User Manual
Page 74
14-9
14. OPERATING PROCEDURES
EM1-31064
14.5 ISSUING LABELS WITH NET WEIGHT STATEMENT (FOR US TYPE ONLY)
14.5 ISSUING LABELS WITH NET WEIGHT STATEMENT (FOR US TYPE ONLY)
Menu: REG., M.DOWN, or REWRAP
Mode: FIX
When the initial settings #1-7 and #1-8 are set to 1, a Net Weight Statement is printed on the label.
A unit price and a tare registered in each PLU are printed as a price and a net weight.
Example) The preset Price is $2.10 and the preset Net Weight is 12 oz. The store knows that the actual
Net Weight of this commodity is 19 oz. and decides to sell it at $2.00.
Enter the PLU #.
8
1
6
2
1
9
3
0
0
PLU
PRT
*
FOR
PRT
*
The label is issued.
The label is issued. (Labels of identical
print data will automatically be issued
consecutively by peeling the label off the
backing paper.)
PLU
C
C
Press:
Enter the new price.
Press:
Enter the new weight.
(unit of weight: oz
displayed in the incremental
display method, i.e., the data
is shifted to the left as each
digit value is entered.)
Press:
Enter the quantity.
Press:
AUTO
MANUAL
Initial set #7-1: 1
Initial set #1-7: 0
Press, to return the PLU data to the
PLU file.
Press, to cancel label
issue temporarily.
Press, to cancel
label issue.
Initial set #7-1: 0
Initial set #7-1: 1