beautypg.com

4 data port, Data port – TANDBERG 700 MXP User Manual

Page 244

background image

TANDBERG 7000 MXP

230

All balanced inputs and outputs (A and B) use balanced line signals according to V.11 (RS422)
and single ended signals in accordance with V.10 (RS423).
For balanced signals a "0"=low voltage is defined as terminal A positive with respect to terminal
B.
For unbalanced signals a "0"= low voltage is defined as terminal positive with respect to GND.

Cable length max: 50 meter


5.1.4 Data

port

The data port(s) are implemented as Data Communications Equipment (DCE). The connector
used are female 9-pin D-subs.

The TANDBERG main camera is normally connected to data port 2 and pin number 4 provides
12V DC / 1 Amps to the main camera. Otherwise the pin-outs for both data ports are the same.

Signal name

Direction

Pin
number

Carrier detect, CD

From
DCE

1

Receive data,
RXD

From
DCE

2

Transmit data,
TXD

To DCE

3

Data terminal
ready, DTR

From
DCE

4

Signal ground,
GND

5

Data set ready,
DSR

From
DCE

6

Ready to send,
RTS

To DCE

7

Clear to send,
CTS

From
DCE

8

Ring indicator, RI

From
DCE

9