THALES DATACRYPTOR User Manual
Page 126

Appendix I: Log and SNMP Trap Numbers
Datacryptor Ethernet User Manual
Page 126
THALES
Log Type
Code
Trap
No.
Severity Message
Information
Audit
75
762
Critical
Primary mode reboot: KAT
test failure
The encryption algorithm
failed a "Known Answer
Test" (KAT) and has
caused the unit to reboot
to attempt to recover.
Audit
76
763
Critical
Secondary mode reboot: KAT
test failure
The encryption algorithm
failed a "Known Answer
Test" (KAT) and has
caused the unit to reboot
to attempt to recover.
Audit
77
764
Major
Hot Standby reboot: FPGA
stats mismatch
Hot standby unit has
detected a possible
problem with the
encryption device and has
caused the unit to reboot
to attempt to recover.
Audit
78
765
Major
Hot Standby reboot: No
response from Private CR
Hot standby unit may
have detected problem
with Host (Private) port
Ethernet interface which
appears to have stopped
responding and has
caused the unit to reboot
to attempt to recover
Audit
79
766
Major
Hot Standby reboot: No
response from Public CR
Hot standby unit may
have detected problem
with Network (Public) port
Ethernet interface which
appears to have stopped
responding and has
caused the unit to reboot
to attempt to recover
Audit
80
767
Major
Hot Standby reboot: Failed to
change IP address
Hot Standby unit:
changing of an IP address
appears to have failed and
has caused the unit to
reboot to attempt to
recover
Audit
81
768
Major
Detected Primary failure: No
response from Public virtual
IP address
Secondary unit has
detected Primary unit
failure on Network (public)
port side
Audit
82
769
Major
Detected primary failure: No
response from Private virtual
IP address
Secondary unit has
detected Primary unit
failure on Host (private)
port side
Audit
83
770
Major
Primary: Response back from
Public virtual IP address
Hot standby: primary unit
has detected itself,
probable configuration
error on public side