Configuring snmp – THALES DATACRYPTOR User Manual
Page 62

Element Manager Reference
Datacryptor Ethernet User Manual
Page 62
THALES
Configuring SNMP
Datacryptor units record all significant management and error events in their logs for later 
examination, but can also be configured to report them immediately to a central location, by 
using the SNMP protocol - to help centralize and simplify management. Events are reported as 
SNMP Traps V1, v2c, or v3 (as selected on the Traps tab – see below), to a central device 
(typically a PC) called an SNMP Network Manager. This SNMP Network Manager must be 
compliant with the SNMP agent version support selection on the Agent Configuration tab – see 
below. A list of the 
with descriptions is provided as an appendix to
this guide.
To configure SNMP, click the SNMP Config button on the unit’s IP Management tab to display 
the SNMP Config dialog. This dialog has two tabs – the Agent Configuration tab and the Traps 
tab. 
Agent Configuration Tab
The Agent Configuration tab lists the SNMP communities defined for this unit, and provides 
facilities to maintain the list. 