9 – External control—CONTROL I/O
TASCAM CD-RW402 Owner’s Manual
51
CONTROL I/O
This connector allows for remote control by suitably-
equipped units, and provides tally information to
such units.
The total current of pin 6 (+5 V) and pin 8 must be
less than 100 mA.
Input signals are active when grounded for at least
30 ms.
Output signals are connected to an open collector
with maximum voltage 15 V, and maximum current
50 mA.
Pin
Signal name
IN/OUT
1
PLAY command (drive 2)
IN
2
STOP command (drive 2)
IN
3
CALL command (drive 2)
IN
4
FADER command (drive 2)
IN
5
Not connected
–
6
+5 V
–
7
Not connected
–
8
+5 V
–
9
Not connected
–
10
PLAY command (drive 1)
IN
11
STOP command (drive 1)
IN
12
CALL command (drive 1)
IN
13
FADER command (drive 1)
IN
14
PLAY tally (drive 2)
OUT
15
READY tally (drive 2)
OUT
16
EOM tally (drive 2)
OUT
17
GND
–
18
Not connected
–
19
Not connected
–
20
Not connected
–
21
Not connected
–
22
PLAY tally (drive 1)
OUT
23
READY tally (drive 1)
OUT
24
EOM tally (drive 1)
OUT
25
GND
–