Symptom

Probable

Cause

Corrective Action

Recommended Tools

NO RPM
READING
500R, 500U


Control Panel/ RPM
Sensor

















Defective Cables








Defective RPM
Sensor Set

• Disconnect 5PA from 5PB. Set meter to

check continuity between 2 and 5 of
5PB. (See Page 18)

• Turn pedals slowly, check continuity

between 2 and 5 of 5PB.

• Does continuity change from off to on?

• If yes – cables and sensor are good –

Replace Control Panel.

• If no – Go to Defective RPM Set.

When the sensor is over the
pickup, continuity will exist.
When sensor is not over pickup,
cicuit will be open.



--------


• Perform continuity checks on all upper

and lower cables.

• Replace defective cables.


--------



• If cables OK- Replace RPM sensor set.





















Multi-meter










Support Services 800-883-8783