Symptom

Probable

Cause

Corrective Action

Recommended Tools

HEAVY

RESISTANCE

750U, 750R

Console Set





Defective Cables









Lower control

Board/Brake

• Remove the console set.

• Disconnect the 7 pin connector from the

back of the console set.

• Pedal.

• Resistance normal? Replace console set.

--------

• Remove pedal and if 3 piece crank

remove crank arm.

• Remove right side cover assembly.

• Disconnect 7- pin connector from the

lower control board.

• Pedal.

• If resistance is normal- replace cable for

console.

--------


• Disconnect 3- pin connector from the

brake.

• Resistance still heavy- Replace brake.

• Resistance normal

• Check brake cables for cross continuity.

• Replace lower control board.


























Multi-meter