11 TROUBLESHOOTING

12 TECHNICAL DATA

Standard:

DECT (Digital Enhanced Cordless Telecommunications)GAP (Generic
Access Profile)

Frequency range:

1880 MHZ to 1900 MHz

Number of channels:

120 duplex channels

Modulation:

GFSK

Speech coding:

32 kbit/s

Emission power:

10 mW (average power per channel)

Range:

300 m in open space /50 m maximum inhouse

Numbr of handsets:

Up to 5

Powersupply base

230V / 50 Hz / 35 mA 6,5V DC 180mA & 150mA Model: SD35-405

Handset Batteries:

2 rechargeable batteries AAA, NiMh 750mAh 1,2V

Handset autonomy:

100 hours in standby

Talk time:

10 hours

Charging time:

6-8 hours

Normal conditions of use:

+5 °C to +45 °C

Flash time

100 or 250 ms

13 DEFAULT SETTINGS

Handset name:

B5400

Auto talk:

ON

PABX code

Empty (Off)

Handset ring volume:

3

Ear volume:

3

Melody Handset:

Internal calls = 1 and external = 5

Menu color:

Blue

Base ring volume:

3

Base ringtone:

1

Pin code:

0000

Key lock:

Off

SMS melody:

On = Morse

Symptom

Possible cause

Solution

No display

Batteries uncharged

Check the position of the batteries

Recharge the batteries

Handset turned OFF

Turn ON the handset

No tone

Telephone cord badly connected

Check the telephone cord connection

The line is occupied by another handset

Wait until the other handset hangs up

The icon

flashes

Handset out of range

Bring the handset closer to the base

The base has no power supply

Check the mains connection to the base

The handset is not registered on the
base

Register the handset on the base

Base or handset do not ring

The ringing volume is zero or low

Adjust the ringing volume

Not possible to transfer a call on PABX

The FLASH time is too short

Set the unit to Long Flash time

Telephone does not react to pressing the
keys

Manipulation error

Remove the batteries and put them back
in place