beautypg.com

Ecc errors detected, How to contact us, 8 ecc errors detected -8 – Texas Memory Systems RAM-SAN 520 User Manual

Page 24: 9 how to contact us -8

background image



power glitches or a serious hardware failure. If a configuration LED stays lit after power-up, do the
following:

• Verify that the oscillator is firmly inserted into its slot. The oscillator is located in the center of the

system motherboard, between the connectors for memory slot 5. The writing on the oscillator should be

oriented in the same direction as the text next to it on the motherboard that reads “50MHz” and “3.3V”.

• Check that the system configuration board is properly seated in its connector at the top of the interface

motherboard. If it has come loose or doesn’t look fully seated, push the board gently back into place.
Make sure it is aligned in its slide rails before pushing the connectors together.

• Make sure that all RAM-SAN internal fans are operational and have unblocked airflow. The RAM-SAN

power supply will go into thermal shutdown if it is not properly cooled. This will cause the power LEDs
to blink as they turns themselves on and off depending upon the internal temperature. If one of the

RAM-SAN power modules turns off, parts of the system will be unable to reconfigure themselves and

will leave the configuration LED on.

• If you suspect that the RAM-SAN has experienced a power surge or glitch, turn off the RAM-SAN, wait

for the internal fans to stop and then turn the system back on.

6.8 ECC Errors Detected

The RAM-SAN hardware has a mechanism for detecting system data errors using an error correction code
(ECC). ECC errors are caused by bits being read from system memory incorrectly and are reported to the

management port. If an ECC error is detected the management port reports:

** ECC error detected


Please follow the steps in section 6.4 to pinpoint the erroneous memory board and/or chip and call Texas

Memory Systems customer support. You will need to be at the RAM-SAN monitor while talking to a

customer support technician, with an error logged on the management port (resetting or turning off the
RAM-SAN will cause the management port to lose the ECC error log).

6.9 How to Contact Us

At Texas Memory Systems, Inc. we strive to meet our customers’ needs by providing quality products and

documentation. This Users Guide will answer many of your initial questions. Please feel free to contact our

Customer Support Department with any additional questions, concerns, or comments regarding your
system.

Texas Memory Systems, Inc.
11200 Westheimer Road, Suite 1000

Houston, TX 77042

www.texmemsys.com
Tel: (713) 266-3200, Fax (713) 266-0332




RAM-SAN User’s Guide

Texas Memory Systems, Inc. (February 7, 2003)

6-8