3.1.3 Communication parameters

„

F10M communication parameters

Parameter name

Title

Setting value

Details

Inverter number

f802

0

to 255

Sets inverter station address. (Note 1)
When using a message transmission, set the address of the
master station to 0 and address of the inverter station to 1 or
over.

Data type
selection

f830

0

, 1

Selects type of transmitting and receiving data.
0: VFA7 mode
1

:μs 250 mode

Input reference
setting 1

f831

Input reference
setting 2

f832

Input reference
setting 3

f833

Input reference
setting 4

f834

Input reference
setting 5

f835

Input reference
setting 6

f836

0

to 16

Sets scan transmission data to be received.

0

: Without setting

1

: Command

2

: Speed reference value

3

: Auxiliary speed reference value

4

: Torque limit value

5

: Positive torque limit value

6

: Negative torque limit value

7

: Torque command value

8

: Synchronized torque bias

9

: Tension torque bias

10

: Load sharing gain

11

: Drooping gain

12

: Speed loop proportional gain

13

: Speed loop accumulative gain

14

: Terminal output data

15

: Inertia moment ratio

16

: Expansion command

Monitor output
setting 1

f841

Monitor output
setting 2

f842

Monitor output
setting 3

f843

Monitor output
setting 4

f844

Monitor output
setting 5

f845

Monitor output
setting 6

f846

0

to 16

Sets scan transmission data to be sent.

0

: Without setting

1

: Status

2

: Operation frequency

3

: Speed feedback value (real time)

4

: Speed feedback value (1-second filter)

5

: Internal torque reference value

6

: Output amperage

7

: Exciting amperage

8

: Torque amperage

9

: Overload accumulative value

10

: Deleted torque of acceleration/deceleration torque

11

: Motor counter data

12

: Error code

13

: Input terminal data

14

: VI input

15

: RR input

16

: RX input