Quantum Data 882E User Manual
Page 41

40
882E Quick Start Guide - HDCP Compliance Testing with Encryption Status Tester (EST) - P/N 68-00210 Rev. B
12. Press the
Tools key get back to the Reports menu.
The generator LCD will display the reports menu as shown below.
13. Select
HDCP to access the HDCP compliance test menu.
The following is displayed on the generator’s LCD.
14. Select
!CompRpt to initiate the HDCP compliance test.
The message “HDCP Compliance Test” is shown and then all the tests are shown in
sequence.
Alternatively, you can run the tests using the following command:
CPTX:CPTR 46
// specifies that all applicable tests will be run.
CPTX:CPTU
// Initiates the execution of the test
Refer to “
To view the HDCP compliance report:
” on page 42 for procedures on how to
view the generated report.
15. (Optional) To run a specific test you can use the command line as shown below:
CPTX:CPTR 37
// Selects specific test (e.g. 3C2_01) see table
below
CPTX:CPTU
// Initiates the execution of the test
You can query the complete list of tests to choose from:
CPTX:GCTN?
// Queries the list of tests supported
You can query the currently selected test to run with:
CPTX:CPTR?
// Queries the selected test to run (see table)
The following table describes the tests that can be performed.
CPTX:CPTR
I
ndex
Test
Description
37
3C_II_01 (Repeater Upstream
w/Transmitter) (Between HDMI
Capable Transmitter and
Repeater)
Regular Procedure: Transmitter – DUT –
Repeater-Receiver
38
3C_II_02 (Repeater Upstream
w/Transmitter) (Between HDMI
Capable Transmitter and
Repeater)
Regular Procedure: HPD After Writing Aksv
EDID
Packets
Misc
HDCP
!CompRpt
EditPCP