882E Quick Start Guide - HDCP Compliance Testing with Encryption Status Tester (EST) - P/N 68-00210 Rev. B
9. Select
Repeater3C device by pressing the adjacent soft key to specify that the device
under test is a repeater.
The following is displayed on the generator’s LCD.
Alternatively, you can specify the device under test as a repeater for the 3C test using
the following commands:
CPTX:DUTT 4
// specifies the device under test as a repeater
for the 3C test.
You can query the current value of the parameter with:
CPTX:DUTT?
// returns the device under test type.
10. (Optional) Specify the remaining parameters in the
EditPCP menu using the table
above.
Alternatively, you can specify the parameters through the command line as follows:
CPTX:RPFT 0
// indicates whether DUT (repeater) supports 1.1
features such as Advanced Cipher and Enhanced
Link Verification. 1 = yes; 0 = no.
CPTX:RKSV 10
// specifies maximum number of downstream devices
that can be supported in the repeater’s KSV list
CPTX:ROOR 0
// indicates whether DUT (repeater) outputs outputs
content to the downstream repeater that does not
have any downstream device connected.
1 = yes; 0 = no.
11. Press the
Options key to save the capabilities definition.
The generator LCD will display the message “Saved”.
12. Press the
Tools key get back to the Reports menu.
The generator LCD will display the reports menu as shown below.
13. Select
HDCP to access the HDCP compliance test menu.
The following is displayed on the generator’s LCD.
Repeater3C
:DUT Type
0
1
+Source_Out_OnlyRep
:Source_Authe_Cnt
:Source_Max_KSV
EDID
Packets
Misc
HDCP
!CompRpt
EditPCP